ACCULINK 316x DSU/CSU

Establishing Access Security on a Port

Although the password feature is available, it is not

required. If used, it ensures access security before control is passed to a device connected to a port. The following procedure is an example only. It shows how to enable the password for the communication port. Passwords can also be enabled for the internal modem and for Telnet sessions.

To establish access security on the communication port,

1.From the Main Menu screen, select Configuration.

The Load Configuration From screen appears.

2.From the Load Configuration From screen, select Current.

The Configuration Edit/Display screen appears.

main/config/user/com Customer ID: Node A Slot: xx

3.From the Configuration Edit/Display screen, select User Interface.

The User Interface Options screen appears.

4.From the User Interface Options screen, select Communication Port.

The Communication Port Options screen appears.

5.In the Password Required field, enter Enable (Figure H-8).

6.Select Save to store this setting in nonvolatile memory.

The Save Configuration To screen appears.

7.From the Save Configuration To screen, select Current.

The password itself is set separately. Refer to the following section, Setting a Password.

Model: 31xx

COMMUNICATION PORT OPTIONS

 

Port Use:

Terminal

 

Port Type:

Asynchronous

 

Data Rate (Kbps):

9.6

 

Character Length:

8

 

Parity:

None

Enable

Stop Bits:

1

Ignore Control Leads:

Disable

Password

Password Required:

Enable

 

Inactivity Timeout:

Enable

 

Disconnect Time (Minutes):

5

 

±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±È±±±±±±±±±±±±±±±±±±±±±±±±±±±±±

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

Figure H-8. Enabling a Password

H-10

January 1997

3160-A2-GB21-50

Page 203