Sending a V.54/ANSI FT1Activation/Deactivation
To send a V.54 or ANSI FT1 Activation or
Deactivation loopback sequence to the far-end DSU/CSU,
1. From the top-level menu screen, select Test.
2. From the Test screen, select Rlpbk.
F1
Test:
Rlpbk Lpbk Ptrns
F2 F3
3. From the Rem Loopback screen, press the
function key that corresponds to the specific
loopback test you want to perform. Use the scroll
keys, if necessary.
F1
Rem Loopback:
LLBUPLLBDN 54UP
F2 F3
The Rem Loop screen appears.
F1
Rem Loop:

Type

Prt1 Prt2 Prt3
F2 F3
The 54UP, 54DN, FT1UP, and FT1DN commands
send the requested sequence out the network
interface on the DS0 channels allocated to the port
you select here.
4. From the Rem Loop screen, press the desired
function key to select the specific port. Use the
scroll keys, if necessary.
After you select a port, the sequence is sent to the
far-end DSU/CSU. During this time, Sending
appears on Line 2 of the LCD, followed by
Command Complete when the sequence is
complete.
During the Sending message, you can press the
and keys without affecting transmission
of the loopback sequence.