ACCULINK 316x DSU/CSU
H-14 January 1997 3160-A2-GB21-50
Sync Data Port Options (Port 1) Front Panel
Equivalent Value (Default in Bold)
Port Type Port Type E530, V.35, RS449, X.21
Port Base Rate Base Rate Nx64, Nx56
Transmit Clock Source Tx Clock Internal, External
Invert Transmit Clock InvertTxC Enable, Disable
Invert Transmit and Received Data InvrtData Enable, Disable
Send All Ones on Data Port Not Ready All Ones Disable, DTR, RTS, Both
Action on Network Yellow Alarm Rcv Yellow None, Halt
Network Init. Data Channel Loopback Net DCLB Disable, V.54, FT1, Both
Port (DTE) Initiated Loopbacks Port LB Disable, DTLB, DCLB, Both
Embedded Data Link EDL Enable, Disable
EDL Management Link Mgmt Link Enable, Disable
Excessive Error Rate Threshold Err Rate 10E–4, 10E–5, 10E–6, 10E–7, 10E–8, 10E–9
Near-End Performance Statistics Near-end Disable, Maintain, Send, Both
Far-End Performance Statistics Far-end Disable, Maintain
Sync Data Port Options (Port 2) Front Panel
Equivalent Value (Default in Bold)
Port Type Port Type E530, V.35, RS449, X.21
Port Base Rate Base Rate Nx64, Nx56
Transmit Clock Source Tx Clock Internal, External
Invert Transmit Clock InvertTxC Enable, Disable
Invert Transmit and Received Data InvrtData Enable, Disable
Send All Ones on Data Port Not Ready All Ones Disable, DTR, RTS, Both
Action on Network Yellow Alarm Rcv Yellow None, Halt
Network Init. Data Channel Loopback Net DCLB Disable, V.54, FT1, Both
Port (DTE) Initiated Loopbacks Port LB Disable, DTLB, DCLB, Both
Embedded Data Link EDL Enable, Disable
EDL Management Link Mgmt Link Enable, Disable
Excessive Error Rate Threshold Err Rate 10E–4, 10E–5, 10E–6, 10E–7, 10E–8, 10E–9
Near-End Performance Statistics Near-end Disable, Maintain, Send, Both
Far-End Performance Statistics Far-end Disable, Maintain