ACCULINK 316x DSU/CSU
3-28 January 1997 3160-A2-GB21-50
8. The configuration option for the data port channel
allocation destination appears on the screen. Select
NET to assign this port to the network interface,
select DTE to assign this port to the DTE
Drop/Insert (DSX-1) interface, or press the
key and the appropriate Function key to assign this
port to another port.
F1
Assign To:NET
Next NET DTE
F2 F3
9. Press F1 (Next) to display the appropriate
configuration options on the screen. Use one of
the following examples, depending on whether
you are assigning by block, ACAMI, or individual
channel.
Block or ACAMI Assignment Method
The Assign By configuration option screen appears
after you select a port.
To assign by the block or ACAMI method,
1. Press F2 for Block or F3 for ACAMI.
F1
Assign By:
Next Block ACAMI
F2 F3
or
F1
Assign By:
Next Block ACAMI
F2 F3
2. Press F1 (Next) to display the next configuration
option (Port Rate).
3. Use the or key to scroll the desired port
rate onto the screen. Rates scroll in groups of
three. Available selections depend on the current
base rate selected for the port. Press the
corresponding Function key to select the port rate.
Then, select Next to display the Start At
configuration option on the screen.
F1
Port Rate:384
Next 64 128
F2 F3
NOTE
For port-to-port mapping, the
procedure is complete after the
port rate is selected.
4. The Start At screen displays the configuration
option used to select the starting DS0 channel. If
the destination selected is the network interface,
then the network channels appear on the screen. If
the destination selected is the DTE Drop/Insert
(DSX-1) interface, then these channels appear on
the screen.
The following screen shows an example for the
network interface. Use the or key to
scroll the desired channel onto the screen. Use the
Function keys to select the starting channel. Only
those DS0 channel numbers that provide enough
bandwidth (based on the configured data rate) to
be used as a starting channel number are
displayed. Channel allocation for this port can
only be cleared by selecting Clear.
F1
Start At:Clear
Next Clear N1
F2 F3