ACCULINK 316x DSU/CSU

DTE Interface Configuration Options

NOTE

These configuration options are only available for 2-port and 4-port DSU/CSUs.

Table C-1

(1 of 2)

DTE Interface Configuration Options

DTE Port: Enab

Next Enab Disab Prev

DTE Drop/Insert (DSX-1) Port. Enables the use of the DTE Drop/Insert (DSX-1) port.

Enab ± Allows the use of the DTE Drop/Insert (DSX-1) interface.

Disab ± Prohibits the use of the DTE Drop/Insert (DSX-1) interface.

NOTE: When this configuration option is disabled, you cannot display or configure any other DTE Interface configuration options. If the clock source configuration option is set to DTE, it is changed to NET.

DTE Framing: ESF (Factory 1) D4 (Factory 2)

Next D4 ESF Prev

DTE Line Framing Format. Designates the framing format for the DTE Drop/Insert (DSX-1) interface.

D4 ± Configures for the D4 framing format.

ESF ± Configures for the Extended Superframe framing format.

DTE Coding: B8ZS (Factory 1) AMI (Factory 2)

Next AMI B8ZS Prev

DTE Line Coding Format. Designates the line coding format to be used on the DTE Drop/Insert (DSX-1) interface.

AMI ± Uses the Alternate Mark Inversion coding format.

B8ZS ± Uses the Bipolar 8 Zero Suppression coding format.

Equal: 0 Ð133

Next 0 Ð133 133 Ð266 266 Ð399 399 Ð533 533 Ð 655 Prev

DTE Line Equalization. Specifies the DTE line equalization compensation parameters that permit a standard DTE Drop/Insert (DSX-1) signal to be delivered over a distance of up to 655 feet.

C-2

January 1997

3160-A2-GB21-50

Page 107
Image 107