Operation

The example shown below assumes that the COM port is being used as the link to the SNMP or Telnet system.

To select the COM port as the SNMP or Telnet link,

1.From the top-level menu screen, select Cnfig.

2.Select the configuration option set to be copied into the Edit area by using the appropriate Function key. Use the scroll keys, if necessary.

3.Select Edit.

4.From the Edit screen, press the key until the User selection appears on the screen.

5.Select User.

Edit:

Chan Gen User

F1 F2 F3

6.Press F1 (Next) until the Com Use configuration option appears.

7.Select Mgmt to configure the COM port as the SNMP or Telnet link.

Com Use:

Next Mgmt ASCII

F1 F2 F3

Setting the IP Address

The IP address is the address used by the SNMP or Telnet system to access the DSU/CSU (see Appendix F, IP Network Addressing Scenarios). For DSU/CSUs using PPP, the IP address can be negotiated if the network device (e.g., router or SNMP manager) supports such negotiation. The IP address is composed of four fields with three digits per field (xxx.xxx.xxx.xxx).

The IP address is set for the MODEM port, the COM port, or the AUX port (with LAN Adapter or daisy chain), depending on which one has been chosen as the SNMP or Telnet communication link. The example below assumes that an IP address of 010.155.111.222 is being set for the COM port. You can use the same principles to assign any value (between 000 and 255 for each digit field) to other ports.

To assign an IP address to the COM port,

1.From the top-level menu screen, select Cnfig.

2.Select the configuration option set to be copied into the Edit area by using the appropriate Function key. Use the scroll keys, if necessary.

3.Select Edit.

4.From the Edit screen, press the key until the Mgmt selection appears on the screen.

5.Select Mgmt.

Edit:

 

 

User

Alarm

Mgmt

F1

F2

F3

6. From the Mgmt Config screen, select Gen.

Mgmt Config:

Gen Trap

F1 F2 F3