Operation
3-173160-A2-GB21-50 January 1997
To select the link layer protocol,
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. From the Edit screen, press the key until the
Mgmt selection appears on the screen.
5. Select Mgmt.
F1
Edit:
User Alarm Mgmt
F2 F3
6. From the Mgmt Config screen, select Gen.
F1
Mgmt Config:
Gen Trap
F2 F3
7. Press F1 (Next) until the Com Link configuration
option appears.
8. Press F2 (PPP) or F3 (SLIP).
F1
Com Link:
Next PPP SLIP
F2 F3
Specifying the Community Name(s) andAccess Type(s)
You have the capability of specifying up to two
community names (community name 1 and community
name 2) to be used by external SNMP managers when
trying to access objects in the DSU/CSU’s MIB. Once you
specify the community name(s), you must then specify the
type of access to the MIB that SNMP managers in the
community are permitted to have.
To specify the community name 1 and its access type,
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. From the Edit screen, press the key until the
Mgmt selection appears on the screen.
5. Select Mgmt.
F1
Edit:
User Alarm Mgmt
F2 F3
6. From the Mgmt Config screen, select Gen.
F1
Mgmt Config:
Gen Trap
F2 F3
7. Press F1 (Next) until the CommunityName1
configuration option appears.