Operation

 

 

 

Table 3-4

 

 

 

Data Port LEDs

 

 

 

 

Name

Color

 

Meaning

 

 

 

DTR

Green

Monitors the state of interchange circuit CD (CCITT 108/1, /2) ± Data Terminal Ready

 

 

received from the synchronous data DTE.

 

 

ON:

DTR is being asserted by the synchronous data DTE.

 

 

OFF:

DTR is not being asserted.

 

 

 

TXD

Yellow

Monitors activity on interchange circuit BA (CCITT 103) ± Transmitted Data. This is the

 

 

data sent from the synchronous data DTE to the data port on the DSU/CSU.

 

 

ON:

Ones are being received from the synchronous data DTE.

 

 

OFF:

Zeros are being received from the synchronous data DTE.

 

 

CYCLING:

Both ones and zeros are being received from the synchronous data

 

 

 

DTE.

 

 

 

RXD

Yellow

Monitors activity on interchange circuit BB (CCITT 104) ± Received Data. This is data

 

 

sent to the synchronous data DTE from the data port on the DSU/CSU.

 

 

ON:

Ones are being sent to the synchronous data DTE.

 

 

OFF:

Zeros are being sent to the synchronous data DTE.

 

 

CYCLING:

Both ones and zeros are being sent to the synchronous data DTE.

 

 

 

CTS

Yellow

Monitors the state of interchange circuit CB (CCITT 106) ± Clear-to-Send sent to the

 

 

synchronous data DTE.

 

 

ON:

CTS is being asserted by the DSU/CSU.

 

 

OFF:

CTS is not being asserted.

 

 

 

RTS

Yellow

Monitors the state of interchange circuit CA (CCITT 105) ± Request-to-Send received

 

 

from the synchronous data DTE.

 

 

ON:

RTS is being asserted by the synchronous data DTE.

 

 

OFF:

RTS is not being asserted.

 

 

 

 

3160-A2-GB21-50

January 1997

3-7

Page 36
Image 36
Paradyne 3160-A2-GB21-50 manual Data Port LEDs, Dtr