ACCULINK 316x DSU/CSU

Table C-6

(2 of 2)

General Configuration Options

Tst Timeout: Enab

Next Enab Disab Prev

Test Timeout. Specifies whether user-initiated loopback and pattern tests have durations that are specified by the Tst Duration configuration option.

Enab ± Loopback and pattern tests initiated on the DSU/CSU have specified durations.

Disab ± Disables test timeout. The tests are terminated manually.

NOTE: For DSU/CSUs that are remotely managed through an inband data stream such as EDL or FDL, the recommended setting is Enab. If tests are inadvertently left in the active state, the Enab setting will allow the test to timeout (terminate) after a specified time.

Tst Duration: 10

Next Up Down Save Prev

Test Duration. Specifies the duration (1 to 120 minutes) of user-initiated loopback and pattern tests. (The Tst Timeout configuration option must be set to Enab.) Use the left or right arrow key to position the cursor on the digit you want to change. Use the Function keys (Up or Down) to increment or decrement the digit.

Up ± Increments the test duration.

Down ± Decrements the test duration.

Save ± Stores the test duration.

C-16

January 1997

3160-A2-GB21-50

Page 121
Image 121
Paradyne 3160-A2-GB21-50 manual Tst Timeout Enab Next Enab Disab Prev, Tst Duration Next Up Down Save Prev