ACCULINK 316x DSU/CSU

Table E-1

(2 of 3)

SNMP MIB to Front Panel Command Cross-Reference

Front Panel Command

SNMP MIB Object

Stat±>ID:

 

Ser

 

Mod

Read the sysDescr object from the System Group

SRev

 

HRevCCA1

 

HRevCCA2

 

 

 

Test±>Rlpbk±>LLBUP

Set dsx1SendCode to dsx1SendLineCode

 

 

Test±>Rlpbk±>LLBDN

Set dsx1SendCode to dsx1SendResetCode

 

 

Test±>Rlpbk±>54UP±>Prtn

Set IfExtnsTestType for port n to testSendV54Up

 

 

Test±>Rlpbk±>54DN±>Prtn

Set IfExtnsTestType for port n to testSendV54Down

 

 

Test±>Rlpbk±>FT1UP±>Prtn

Set IfExtnsTestType for port n to testSendFT1UP

 

 

Test±>Rlpbk±>FT1DN±>Prtn

Set IfExtnsTestType for port n to testSendFT1Down

 

 

Test±>Lpbk±>LLB

Set dsx1LoopbackConfig for Net T1 to dsx1LineLoop

Test±>Lpbk±>Abort±>LLB

Set dsx1LoopbackConfig for Net T1 to dsx1NoLoop

 

 

Test±>Lpbk±>PLB

Set dsx1LoopbackConfig for Net T1 to dsx1PayloadLoop

Test±>Lpbk±>Abort±>PLB

Set dsx1LoopbackConfig for Net T1 to dsx1NoLoop

 

 

Test±>Lpbk±>DLB

Set dsx1LoopbackConfig for DTE T1 to dsx1LineLoop

Test±>Lpbk±>Abort±>DLB

Set dsx1LoopbackConfig for DTE T1 to dsx1NoLoop

 

 

Test±>Lpbk±>RLB

Set dsx1LoopbackConfig for DTE T1 to dsx1PayloadLoop

Test±>Lpbk±>Abort±>RLB

Set dsx1LoopbackConfig for DTE T1 to dsx1NoLoop

 

 

Test±>Lpbk±>DCLB±>Prtn

Set IfExtnsTestType for port n to testFullDuplexLoopBack

Test±>Lpbk±>Abort±>DCLB±>Prtn

Set dsx1LoopbackConfig for port n to noTest

 

 

Test±>Lpbk±>DTLB±>Prtn

Set IfExtnsTestType for port n to testLoopDTLB

Test±>Lpbk±>Abort±>DTLB±>Prtn

Set dsx1LoopbackConfig for port n to noTest

 

 

Test±>Ptrns±>Send±>QRSS±>NET

Set dsx1SendCode for Net T1 to dsx1SendQRSS

Test±>Ptrns±>Abort±>Send±>NET

Set dsx1SendCode for Net T1 to dsx1SendNoCode

 

 

Test±>Ptrns±>Send±>QRSS±>Prtn

Set IfExtnsTestType for port n to testSendQRS

Test±>Ptrns±>Abort±>Send±>Prtn

Set IfExtnsTestType for port n to noTest

 

 

Test±>Ptrns±>Send±>1in8

Set dsx1SendCode for Net T1 to dsx1SendOtherTestPattern

Test±>Ptrns±>Abort±>Send±>NET

Set dsx1SendCode for Net T1 to dsx1SendNoCode

 

 

Test±>Ptrns±>Send±>511±>Prtn

Set IfExtnsTestType for port n to testSend511

Test±>Ptrns±>Abort±>Send±>Prtn

Set IfExtnsTestType for port n to noTest

 

 

Test±>Ptrns±>Mon±>QRSS±>NET

Set ifExtnsTestType for Net T1 to testMonQRSS

Test±>Ptrns±>Abort±>Mon±>NET

Set ifExtnsTestType for Net T1 to noTest

 

 

Test±>Ptrns±>Mon±>QRSS±>Prtn

Set ifExtnsTestType for port n to testMonQRSS

Test±>Ptrns±>Abort±>Mon±>Prtn

Set ifExtnsTestType for port n to noTest

 

 

E-18

January 1997

3160-A2-GB21-50

Page 183
Image 183
Paradyne 3160-A2-GB21-50 Set dsx1LoopbackConfig for Net T1 to dsx1LineLoop, Set dsx1LoopbackConfig for port n to noTest