ACCULINK 316x DSU/CSU
C-36 January 1997 3160-A2-GB21-50
Table C-10
(2 of 2)
Management Trap Configuration Options
Entp Trap: Enab
Next Enab Disab Prev
Enterprise Specific Traps. Specifies whether enterpriseSpecific traps are enabled.
Enab – Sends trap messages for enterpriseSpecific events to the currently configured trap manager(s).
Disab – Disables the sending of trap messages for enterpriseSpecific events.
NOTE: This configuration option is not available if the SNMP Trap configuration option (in the

Alarm Configuration

Options

section on page C-25) is disabled.
Link Trap: Both
Next Disab Up Down Both Prev
Link Trap Type. Specifies the link trap type to enable. Interfaces monitored for linkUp and linkDown traps are specified
with the Trap I/F configuration option.
Disab – Disables the sending of trap messages for linkDown or linkUp events.
Up – Sends trap messages for linkUp events to the currently configured trap manager(s).
Down – Sends trap messages for linkDown events to the currently configured trap manager(s).
Both – Sends trap messages for linkUp and linkDown events to the currently configured trap manager(s).
NOTE: This configuration option is not available if the SNMP Trap configuration option (in the

Alarm Configuration

Options

section on page C-25) is disabled.
Trap I/F: All
Next NET DTE T1s Ports All Prev
Link Trap Interfaces. Specifies which interfaces generate linkUp and linkDown trap messages. These traps are supported
on the T1 interfaces (network and DTE Drop/Insert) and the synchronous data ports.
NET – Sends trap messages for linkUp and linkDown events occurring on the network interface.
DTE – Sends trap messages for linkUp and linkDown events occurring on the DTE Drop/Insert (DSX-1) interface. This
selection does not appear if the DTE Drop/Insert (DSX-1) interface is disabled.
T1s – Sends trap messages for linkUp and linkDown events occurring on the network or DTE Drop/Insert (DSX-1)
interface.
Ports – Sends trap messages for linkUp and linkDown events occurring on the synchronous data ports.
All – Sends trap messages for linkUp and linkDown events occurring on the network interface, DTE Drop/Insert (DSX-1)
interface, or the synchronous data ports.
NOTE: This configuration option is not available if the Link Trap configuration option is not configured to generate trap
messages for linkUp or linkDown events.