Maintenance

Table 4-3

(1 of 2)

Performance Registers

Register

Interval Description

Totals Description

 

 

 

Event

ESF error events counter. An error event is an

N/A

 

ESF frame with either a Cyclic Redundancy

 

 

Check (CRC) error or an Out Of Frame (OOF)

 

 

event. The maximum count is 65,535. This

 

 

register is only reset as a result of a reset

 

 

command from the network. This register is

 

 

valid for the current interval only.

 

 

 

 

CurTimer

Current interval timer. This register records the

N/A

 

number of seconds in the current 15-minute

 

 

interval. The maximum is 900 seconds. This

 

 

register is valid for the current interval only.

 

 

 

 

VldIntvl

N/A

Valid interval total. Records the number of valid

 

 

15-minute intervals in the previous x hours, where x

 

 

is 24 hours for aggregate performance and 8 hours

 

 

for port performance. This register is not valid for the

 

 

current interval.

 

 

 

ES

The number of errored seconds for the current

The total number of errored seconds for the previous

 

interval. An errored second is any second with

x hours, where x is 24 hours for aggregate

 

one or more ESF error events. The maximum is

performance and 8 hours for port performance.

 

900 seconds.

 

 

 

 

UAS

The number of unavailable seconds for the

The total number of unavailable seconds for the

 

current interval. An unavailable second is any

previous x hours, where x is 24 hours for aggregate

 

one second interval when service is

performance and 8 hours for port performance.

 

unavailable. (Detection occurs with

 

 

10 consecutive unavailable seconds.) The

 

 

maximum is 900 seconds.

 

 

 

 

SES

The number of severely errored seconds for the

The total number of severely errored seconds for the

 

current interval. A severely errored second is

previous x hours, where x is 24 hours for aggregate

 

any second with 320 or more CRC errors, or

performance and 8 hours for port performance.

 

any second with one or more OOF events. The

 

 

maximum is 900 seconds.

 

 

 

 

BES

The number of bursty errored seconds for the

The total number of bursty errored seconds for the

 

current interval. A bursty errored second is any

previous x hours, where x is 24 hours for aggregate

 

second with more than one, but less than 320,

performance and 8 hours for port performance.

 

CRC errors. The maximum is 900 seconds.

 

 

 

 

LOFC

The loss of frame count for the current interval.

The total loss of frame count for the previous x

 

This is a count of the number of times that an

hours, where x is 24 hours for aggregate

 

LOF is declared. The maximum count is 255.

performance and 8 hours for port performance.

 

 

 

CSS

The number of controlled slip seconds for the

The total number of controlled slip seconds for the

(Not valid for

current interval.

previous x hours, where x is 24 hours for aggregate

Port registers.)

 

performance and 8 hours for port performance.

 

 

 

3160-A2-GB21-50