ACCULINK 316x DSU/CSU

Port Configuration Options

 

Table C-2

 

(1 of 5)

 

Port Configuration Options

 

 

Port Type: E530 (Factory 1)

V.35 (Factory 2)

Next E530 V.35 RS449

X.21 Prev

 

 

Data Port Type. Allows selection of the data port interface type.

E530 ± Configures the port as an EIA 530A compatible interface. EIA 530A DTEs can be directly connected to a port connector on the back of the DSU/CSU.

V.35 ± Configures the port as a V.35 compatible interface. V.35 DTEs can be connected to a port connector using an EIA 530A-to-V.35 adapter cable.

RS449 ± Configures the port as an RS449 compatible interface. RS449 DTEs can be connected to a port connector using an EIA 530A-to-RS449 adapter cable.

X.21 ± Configures the port as an X.21 compatible interface. X.21 DTEs can be connected to a port connector using an EIA 530A-to-X.21 adapter cable.

NOTE: If this configuration option is set to X.21, set the All Ones configuration option to RTS or Disab.

Base Rate: Nx64

Next Nx64 Nx56 Prev

Data Port Base Rate. Allows selection of the base rate for the data port. The data rate for the port is a multiple (from 1 to 24) of the base rate specified with this configuration option.

Nx64 ± Sets the base rate for this port to 64 kbps. The data rate is Nx64 kbps, where N is a number from 1 to 24.

Nx56 ± Sets the base rate for this port to 56 kbps. The data rate is Nx56 kbps, where N is a number from 1 to 24.

Net DCLB: Disab (Factory 1)

Both (Factory 2)

Next Disab V.54 FT1

Both Prev

 

 

Network Initiated DCLB. Allows the initiation and termination of a Data Channel Loopback (V.54 loop 2) by the receipt of a V.54 DCLB-actuate sequence or DCLB-release sequence from the network or far-end device. The sequences may be either V.54 or FT1 (ANSI) compliant sequences.

Disab ± Ignores the DCLB-actuate and DCLB-release sequences for this port.

V.54 ± Enables DCLB-actuate and DCLB-release sequences that comply with the V.54 standard for ``Inter-DCE signaling for point to point circuits.º

FT1 ± Enables DCLB-actuate and DCLB-release sequences that comply with the ANSI T1.403, Annex B standard for ``In-band signaling for fractional-T1 (FT1) channel loopbacks.º

Both ± Enables DCLB-actuate and DCLB-release sequences that comply with either the ANSI or V.54 standard. The type of actuate and release sequences do not have to match.

C-4

January 1997

3160-A2-GB21-50

Page 109
Image 109
Paradyne 3160-A2-GB21-50 manual Port Configuration Options, Table C-2, Port Type E530 Factory Next E530 V.35 RS449 Prev