PYROMASTER@ UVHB26 Vent-Free Heaters
OPERATING INSTRUCTIONS
FIRST FIRING
Upon completing the gas line connection, a small amount of air will be trapped in the line. When first lighting the unit with pilot light, it will take a few minutes to purge the trapped air. Once purging is complete, the pilot and burner will light and oper- ate as indicated in the instruction manual. Subse- quent lightings of the appliance will not require purging.
When lit for the first time, the appliance will emit a slight odor for an hour or two. This is due to paint and lubricants used in the manufacturing process. After each lighting, vapor may condense and fog the glass; this moisture disappears in a few min- utes of burning.
. SAFETY PRECAUTIONS FOR
STANDING PilOT HEATERS
FOR YOUR SAFETY - READ THIS SECTION BEFORE LIGHTING!
repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
C. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of this control system and any gas control which has been underwater.
LIGHTING INSTRUCTIONS FOR HONEYWELL
1.STOP! Read the safety information above.
2.To access the controls, Remove lower louvre.
3.Turn wall switch and wireless remote OFF (if used).
4.Push in gas control knob slightly and turn
clockwise ~ to OFF. See figure 10.
A WARNING: IF YOU DO NOT
FOllOW THESE INSTRUCTIONS
EXACTLY, A FIRE OR EXPLO- SION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR lOSS
OF LIFE.
A. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to floor because some gas is heavier than air and will settle on the floor.
IF YOU SMELL GAS:
1.Do not try to light any appliance.
2.Do not touch electrical switches; do not
use any phone in your building.
3.Immediately call your gas supplier from a neighbor's phone. Follow your gas supplier's instructions.
4.If you cannot reach your gas supplier, call the fire department.
B.Use only your hand to push in or turn the gas valve control knob. Never use tools. If the
knob will not push in or turn by hand, don'ttry to
5.WAIT 5 MINUTES TO CLEAR OUT ANY GAS. If you then smell gas, STOP! Follow A in the safety information. If you do not smell gas, go to next step.
BLACK
JUMPER
~ | "~ | PIEZO IGNITOR |
HED
PILOT
FP829
Fig. 10. Honeywell valve and pilot assembly.
11