PYROMASTER@ UVHB26 Vent-Free Heaters

DESCRIPTION

The UVHB vent-free heaters is designed to be installed into a FPS1212 or FPS1214 mantel

cabinet only. It may not be installed in any other manner.

GAS SPECIFICATIONS

Model Fuel Gas Control

Max. Min.

Input Input B.T.U.H. B.T.U.H.

UVHB26RN Natural MillivoltsHi/lo 26,000 18.200

The UVHB26 is available in Natural or Propane gas, equipped with an oxygen depletion sensor with a standing pilot.

UVHB26RP Propane MillivoltsHi/lo 26,000 19,500

Fig. 2. Gas spectications.

MINIMUM CLEARANCES

Minimum clearance to combustibles are main- tained when the UVHB26 is installed into the FPS1212 or FPS1214 mantel cabinets. Top of unit to ceiling minimum 42 inches.

. GAS SUPPLY PRESSURES

PLANNING

Planning the installation is an important first step: it will save time and money later in the actual installation. In planning the installation, consider:

1. Where the heater will be located.

'j

/

This heater must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure equal to or less than 1/2 psig (3.45 kPa).

2. All components needed to complete the

project.

'..,:,..' The heater and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa).

 

NATURAL

LP

Inlet Minimum

4.5"W.e.

11"W.e.

Inlet Maximum

10.5" w.e.

13"W.e.

Input Adjustment

7.0"W.e.

11"W.e.

Manifold Pressure

3.5"W.e.

10"W.e.

Table 1. Gas supply pressures.

HIGH ELEVATION DERATING

Input ratings are shown in BTU per hour and are for elevations up to 4,500 (1370m) feet.

For elevations above 4,500 (1370m) feet, ratings should be reduced at the rate of four (4) percent for each 1,000 feet above sea level.

'\

,.'

coo.'"

5

Image 5 Contents
For Your Safety Please Read this Manual Before Installing Using ApplianceTablb Contents OFYOURPYROMASTERVEN~FREEROOM Safety DevicesGeneral Information ~I§§§I~ Description GAS SpecificationsPlanning High Elevation DeratingINSTAllATION RUN GAS Line from ITS Source to the Heater FAN Operation PYROMASTER@ UVHB26 Vent-Free HeatersBottom Louvre Grille Removal GAS Heater to a 120V PowerLava Rock Lighting Instructions for Honeywell Operating InstructionsFirst Firing To Turn OFF GAS to Appliance PYROl1ASTER@UVHB26 Vent-Free HeatersCleaning the Standing Pilot Control System Maintenance~I~~~I~ Flame AdjustmentTKOUBLESUOOTING. Uoneywell VS8421 Accessories AccessoriesRM4 GwskF1 \f. \ UVUB26 Replacement PartsPartno Replacement Parts UVC SeriesPage Limited 2/20 Year Warranty