Euro-Pro UV209H owner manual Using the Air Driven Turbo Brush, Cleaning Air Driven Turbo Brush

Page 7

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

Using the Air Driven Turbo Brush

Warning: To reduce the risk of electric shock, the power cord must be disconnected before removing the dust cup, HEPA filter,changing the filters or performing maintenance/trouble shooting checks.

Note: The Air Driven Turbo Brush may be used with the flexible hose alone or with the extension tubes as well.

To use with the flexible hose:

1.Remove the flexible hose from the hose connector. (Fig. 19)

Hose

Connector

 

Hand Held Air Driven

Fig. 19

Turbo Brush

Fig. 20

2.Push the Air Driven Turbo Brush (Fig. 20) onto the end of the flexible hose to use.

3.To remove the Air Driven Turbo Brush from the flexible hose, pull and twist.

To use with the extension tubes:

1.Attach the extension tubes onto the end of the flexible hose following the instructions above.

2.Push the Air Driven Turbo Brush onto the end of the extension tube.

3.To remove, pull and twist as above.

The efficiency of your Air Driven Turbo Brush depends on the bristle brush rotating at high speed. Strong air suction is needed to accomplish this. In order to endure that maximum air suction is maintained, please read the following instructions:

Cleaning Air Driven Turbo Brush

Locking Latch

Tilt

Upwards

Fig. 21

Turbine

1.Slide locking latch forward then tilt the top housing of the brush upwards. The top housing is hinged and will tilt up approximately 45° only. (Fig. 21)

2.Inspect turbine wheel and air passage for debris and/or blockage. Remove debris if present.

3.Inspect the rotating brush for built-up hair or string. If present, remove by carefully cutting with scissors. Avoid damaging or cutting bristles.

4.Once clean, close the top cover of the turbo brush and slide the locking latch toward the rear of the brush to lock.

Motor Thermostat

Important: This unit is equipped with a motor protective thermostat. If for some reason the vacuum cleaner should overheat, the thermostat will automatically turn the unit off. Should this occur:

Push the On/Off button once.

Disconnect the plug from the

 

power source.

Check the source of overheating

 

problem. (i.e. clogged hose or

 

filter)

• If clogged hose or filter is found,

 

unclog the hose and replace the

 

filters.

Wait at least 45 minutes before

 

attempting to reuse the vacuum.

After unit has cooled down for

 

45 minutes, plug in the cleaner

Carpet Height Selector

This upright vacuum can be used on multiple types of carpeting, bare floors or upholstery with attachments.

To select a pile height setting:

1.Turn vacuum cleaner "Off".

2.Select a pile height setting by sliding the carpet height selector to the desired setting. (Fig. 4)

Fig. 4

Suggested Pile Height Setting:

You may need to raise the height of the vacuum to make some jobs easier, such as scatter rugs and longer pile carpets. Suggested settings are:

HIGH: shag carpet, long pile, plush scatter rugs, tools

MED: medium to long pile

LOW: short to medium pile, bare floors

FLOOR: very low pile, bare floors

Place unit in "HIGH" setting when using attachments to prevent possible floor damage. Always set the Carpet to Floor selector to “Floor” setting when using the accessories. (Fig. 5)

Attention: Special care is required when vacuuming certain types of carpet or floor covering. Always check the carpet or floor covering manufacturer's recommended cleaning instructions before vacuuming.

Removing & Emptying Dust Cup

Warning: To reduce the risk of electric shock, the power cord must be disconnected before removing the dust cup, dust cup filter,changing the filters or performing maintenance/trouble shooting checks.

The “Dust Cup” must always be emptied when the dirt level reaches the "FULL" line on the dust cup. To remove the dust cup from the vacuum:

1.Press down on the dust cup release button that is located on the handle of the dust cup. (Fig. 6)

2.Holding the dust cup from the handle, pull the dust cup out from the vacuum. (Fig. 7)

3.To empty the dust cup, hold it by the handle over a garbage can and press on the trap door release button to empty. (Fig. 8)

Fig. 6

Fig. 7

Trap Door

Release

1.Empty the Dust Cup frequently during use.

2.Always “TapClean” the HEPA dust cup filter each time the dust cup is emptied.

3.Ensure that the rotating bristle brush is kept free of hair and string.

4.Inspect the turbine regularly to ensure that the air passage is free of dirt and debris.

and push the On/Off button. The

vacuum should start again.

• If the vacuum still does not start,

contact customer service at

1 (800) 798-7398.

8

Fig. 5

Fig. 8

5

Image 7
Contents Model UV209H Bagless Upright VacuumMain Mill Street, Door Plattsburgh, NY 800 Model UV209H Ownership Registration CardRev /03D Important Safety InstructionsOr for Technical Support For Model UV209H To Order Replacement Filters or BeltsPrecautionary Measures Cyclonic Bagless UprightGetting to Know Your Bagless Cyclonic Upright Problem SolvingOperating Instructions Carpet Height Selector Using the Air Driven Turbo BrushCleaning Air Driven Turbo Brush Motor ThermostatCleaning the Secondary Filter Cleaning the Hepa Dust Cup FilterCleaning the Hepa Filter Frame Cleaning the Filter Ring

UV209H specifications

The Euro-Pro UV209H is a cutting-edge handheld vacuum that merges powerful suction capabilities with advanced filtration technologies, making it an ideal choice for both everyday cleaning tasks and more specialized cleaning needs. Designed with the modern user in mind, it boasts a compact and lightweight design, allowing for easy maneuverability and storage.

At the heart of the UV209H is its robust motor, which provides impressive suction power. This ensures that dirt, dust, and debris can be easily lifted from various surfaces, including carpets, upholstery, and hard floors. The vacuum's versatility is complemented by multiple attachments, such as crevice tools and upholstery brushes, designed to tackle a wide range of cleaning challenges.

One of the standout features of the Euro-Pro UV209H is its innovative HEPA filtration system. This advanced technology captures 99.97% of dust and allergens, making it an excellent choice for allergy sufferers and families with pets. The washable filter not only enhances the vacuum’s performance but also contributes to a more eco-friendly cleaning experience, as users can easily maintain it without the need for frequent replacements.

The Euro-Pro UV209H is also designed with user convenience in mind. It features a large dustbin that minimizes the frequency of emptying, allowing for longer cleaning sessions without interruption. The vacuum's ergonomic handle and controls ensure comfortable usage, reducing strain during extended periods of operation.

Additionally, the vacuum is equipped with a powerful lithium-ion battery, offering cordless operation for maximum flexibility and ease of use. This feature is particularly advantageous for cleaning hard-to-reach areas or taking the vacuum outside without the hassle of cords.

Durability is another key characteristic of the Euro-Pro UV209H. It is constructed with high-quality materials designed to withstand regular use, ensuring that it remains a reliable cleaning companion for years to come.

In summary, the Euro-Pro UV209H combines powerful suction, advanced HEPA filtration, and user-friendly features, making it a top choice for anyone looking to maintain a clean and healthy living environment. Its thoughtful design and innovative technologies make cleaning not only effective but also enjoyable.