THE BRUSHES
When brushes are worn and bris- tles do not touch the edge of a card held across the nozzle, they should be replaced. Always replace both brushes at the same t i m e t o m a i n t a i n c l e a n i n g efficiency.
TO REPLACE THE
BRUSHES
| Remove bottom plate, belt, and | |
| agitator, | following directions |
| given on Page 10. | |
| 1. Turn end plates of agitator | |
| in opposite directions until | |
3 | one plate comes off. | |
|
| |
| 2. Then pry out end section as | |
| shown | in illustration. |
3. After end section is removed, tap the shaft gently with a hammer.
4. Pull other plate and shaft from agitator.
5. Remove brushes b,: pulling them from agitator \vIth pliers. Slide new brushes into the channels - small ends first - pushing them in as far as possible.
6. Replace end plate and shaft lining up locator on shaft with slot on agitator. Re- place other end section and end plate and tighten.
11