Furuno LH-3000 manual Sailing signal, Towing signal, Stop signal

Page 21

 

2. OPERATION

SAIL:

Warning signal for sailboats, tug boats and tow boats underway. One 3-second

 

blast, followed by one 2-second interval, one 1-second blast, one 2-second

 

interval and one 1-second blast. Repeated every 120 seconds.

 

1 s

2 s

2 s

1 s

3 s

 

 

 

120 s

 

 

 

 

 

 

 

 

 

Sailing signal

TOW:

Warning signal for vessels under tow. One 3-second blast, followed by one

 

2-second interval, one 1-second blast, one 2-second interval, one 1-second blast,

 

one 2-second interval, and one 1-second blast. Repeated every 120 seconds.

 

 

 

2 s

1 s

2 s

1 s

2 s

1 s

3 s

120 s

Towing signal

STOP: Warning signal for power-driven vessel that is stationary. Two 3-second blasts, with a 2-second interval between each blast, repeated every 120 seconds.

3 s

2 s

 

 

 

 

 

 

 

 

 

3 s

120 s

Stop signal

15

Image 21
Contents Loud Hailer Page Safety Instructions Table of Contents Foreword FeaturesWord to the Owner of the LH-3000 IiiEquipment List System ConfigurationStandard supply Optional supplyMounting procedure InstallationMounting the Loud Hailer Mounting considerationsFlush mounting Contents of flush mount kitName Type Code No Qty Loud hailer, flush mountIntercom speaker Intercom Speaker optionWiring Rear panel layoutLH-3000, rear panel LH-3000, rear panel, how to wire terminals WiringPower connection Intercom speaker optionFabrication of speaker cable Burglar alarm local supply Hailer horn local supplyFabrication of cable TTYCS-1 Output power Floating groundStereo plug Controls Operational OverviewControl description LH-3000, front viewTurning the Power On/Off Adjusting Output Level Adjusting Key BacklightingAdjusting Listening Volume Calling All Intercom StationsReceiving a Call from an Intercom Station Calling a Specific Intercom StationAutomatically selecting a single calling station Automatically selecting multiple calling stationsHailing by Voice Manually selecting a calling stationIntercom station operation Description of warning signals Sounding Warning SignalsManual warning signals Automatic warning signalsSailing signal Towing signalStop signal Sounding a manual warning signal Anchor signalAground signal Calling intercom stations while sounding warning signals Sounding an automatic warning signalCalling all intercom stations Calling a specific intercom stationTransmitting the Auxiliary Signal Transmitting the auxiliary signal over all speakersReturning auxiliary transmission to standby mode Enabling the alarm mode Alarm ModeWhen an attempt is made to remove the Loud Hailer Disabling the alarm modeAlarm setting/cancel flow Preventive Maintenance MAINTENANCE, TroubleshootingCleaning General checksTroubleshooting table TroubleshootingReplacing the Fuse If… Then…LH-3000 Furuno Specifications of Loud HailerPacking List LH-3000 フラッシュマウントキット Page Page Page Page Hatai Page 00014911800