Furuno LH-3000 manual Alarm setting/cancel flow

Page 26

2. OPERATION

Enable alarm

Press the [Lower Signal

Select] key to flash the YELP indicator.

Press the [FUNC] key.

An attempt is made to remove the Loud Hailer with alarm mode active

ALL, FWD, AFT and BOTH indicators light.

YELP indicator goes off.

After 5 minutes

ALL, FWD, AFT and BOTH indicators go off.

BOTH indicator lights every four seconds.

STANDBY STATUS (Alarm mode enabled)

Alarm sound is released through both horn speakers at maximum volume.

Silence/cancel alarm

Press any key except AUX or DIM, or turn off the power.

Alarm setting/cancel flow

20

Image 26
Contents Loud Hailer Page Safety Instructions Table of Contents Word to the Owner of the LH-3000 FeaturesForeword IiiStandard supply System ConfigurationEquipment List Optional supplyMounting the Loud Hailer InstallationMounting procedure Mounting considerationsName Type Code No Qty Contents of flush mount kitFlush mounting Loud hailer, flush mountIntercom Speaker option Intercom speakerLH-3000, rear panel WiringRear panel layout Wiring LH-3000, rear panel, how to wire terminalsFabrication of speaker cable Power connectionIntercom speaker option Fabrication of cable TTYCS-1 Burglar alarm local supplyHailer horn local supply Stereo plug Output powerFloating ground Control description Operational OverviewControls LH-3000, front viewTurning the Power On/Off Adjusting Listening Volume Adjusting Key BacklightingAdjusting Output Level Calling All Intercom StationsAutomatically selecting a single calling station Calling a Specific Intercom StationReceiving a Call from an Intercom Station Automatically selecting multiple calling stationsIntercom station operation Hailing by VoiceManually selecting a calling station Manual warning signals Sounding Warning SignalsDescription of warning signals Automatic warning signalsStop signal Sailing signalTowing signal Aground signal Sounding a manual warning signalAnchor signal Calling all intercom stations Sounding an automatic warning signalCalling intercom stations while sounding warning signals Calling a specific intercom stationReturning auxiliary transmission to standby mode Transmitting the Auxiliary SignalTransmitting the auxiliary signal over all speakers When an attempt is made to remove the Loud Hailer Alarm ModeEnabling the alarm mode Disabling the alarm modeAlarm setting/cancel flow Cleaning MAINTENANCE, TroubleshootingPreventive Maintenance General checksReplacing the Fuse TroubleshootingTroubleshooting table If… Then…Furuno Specifications of Loud Hailer LH-3000Packing List LH-3000 フラッシュマウントキット Page Page Page Page Hatai Page 00014911800