Enerco TSIR20NGT, TSBF10NG Thermostat Control Operation, Inspecting Burner, Pilot Flame Pattern

Page 12

8.When the pilot is lit, turn control know counter- clockwise to heating level. The main burner should light.

9.To select the desired heat level, turn the tem- perature setting knob counterclockwise to between 1 & 7.

THERMOSTAT CONTROL OPERATION

FOR IR20NGT / IR30NGT: The thermostatic control used simply turns on and off the burner.

FOR BF20NGT / BF30NGT: The thermostatic control used modulates the flame size as the temperature gets closer to set point, then it turns off the burner upon reaching temperature.

The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between 1 and 7. Selecting the HI setting will cause the burner to remain on.

Note: The thermostat sensing bulb measures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, insulation location, room size, open air temperature, etc.). Frequent use of your heater will let you determine your own comfort levels.

TO TURN OFF GAS TO APPLIANCE

SHUTTING OFF HEATER

1.Turn control knob clockwise to the OFF posi- tion.

2.Turn off all electrical power to the appliance if servicing is to be preformed.

3.Turn off equipment shutoff valve.

SHUTTING OFF BURNER ONLY (PILOT STAYS LIT)

1.Turn control knob clockwise to the PILOT/IGN position.

INSPECTING BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 21 show a correct pilot flame pattern. Figure 22 shows an incorrect pilot flame pattern. The incorrect pilot flame pattern is not touching thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 22:

Turn heater off (see To Turn OFF Gas to Appliance, page 11 for non-thermostat models or page 12 for thermostat models).

See Troubleshooting, pages 14 and 15.

Figure 21

Figure 22

BURNER FLAME PATTERN

Figure 23 show a correct burner flame pattern. Figure 24 shows an incorrect burner flame pattern. If burner flame pattern is incorrect, as shown in Figure 24:

Turn heater off (see To Turn OFF Gas to Appliance, page 11 for non-thermostat models or page 12 for thermostat models).

See Troubleshooting, pages 14 and 15.

Figure 23a.

Figure 23b.

Figure 24a.

12 Installation instructions and Owner’s Manual 70574 REV. C 8/05

Image 12 Contents
Blue Flame Heaters Plaque Heaters MHBF30NGT MHBF20NGTTSBF20NGT TSBF10NG TSBF30NGT MHIR30NGT MHIR20NGT TSIR30NGT TSIR20NGT TSIR10NGPrecautions Carbon Monoxide PoisoningNatural Gas Safety Device Thermostatic Control on Thermostat ModelsLocal Codes Ignition SystemDetermining the Type of Heater Location Space Ventilation AIRVentilation from Inside Building Installation This Installation RequiresLocating Heater Ventilation from OutdoorsFastening Heater to Wall Mounting BracketConnecting to GAS Supply Floor Mounting Away from Wall Test pressure in Excess of ½ psig 3.5kPa Pressure Testing Heater Gas Connections Electrical Wiring DiagramWhat to do if YOU Smell GAS Lighting Instructions To Turn OFF GAS to Appliance Operating Your Heater Thermostat ModelsShutting OFF Heater Shutting OFF Burner only Pilot Stays LITThermostat Control Operation Inspecting BurnerPilot Flame Pattern Burner Flame PatternCleaning and Maintenance Cleaning ODS/PILOT and BurnerCleaning Burner Pilot AIR Hole Inlet Cleaning Heater CabinetTroubleshooting Observed Symptom Possible Cause RemedyTroubleshooting CON’T Observed Symptom Possible Cause RemedySpecifications IR10NG IR20NGT IR30NGTBF10NG BF20NGT BF30NGT Replacement Parts Parts Under WarrantyParts not Under Warranty Technical ServiceThermostat models BF20NGT BF30NGTIR20NGT20-235 IR30NGTParts List Description QTYIR20NGT BF20NGT IR30NGT BF30NGT Regulator to Thermostat Valve tube Ass’y MHIR10NG, MHBF10NG, TSIR10NG, TSBF10NG NON-Thermostat modelsIR10NG BF10NGMHIR10NG, MHBF10NG, TSIR10NG, TSBF10NG IR10NG BF10NGDescription QTY Warranty Information