Boiler Ratings and Capacities

Boiler Ratings and Capacities

FIG. 1 - INDOOR BOILERS

BURNER TYPE

AFG - OIL

CF375 - OIL

AFG W/AIR

G2T - GAS

RIELLO

INTAKE BOOT

40 SERIES - OIL

 

 

 

 

 

 

 

 

 

 

 

X

11½

14

18

13½

167/

8

Y

11

15

10½

137/

16

 

 

 

INDOOR OIL-FIRED HOT WATER BOILERS

 

 

 

 

 

 

 

MODELS LESS TANKLESS COIL

 

 

 

 

RECOMMENDED

HEATING

 

NET I=B=R

ANNUAL FUEL

STEADY STATE

NO.

FLUE

LENGTH

M ODEL

FIRING RATES

CAPACITY

 

RATING

UTILIZATION

"A"

 

EFFICIENCY %

SEC.

SIZE

 

GPH

 

M BH

 

MBH

EFFICIENCY%

DIMENSION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1

 

Note 2

Note 3

 

 

 

 

PFO-3

Minimum

.45

56

 

48

87.5

88.22

3

5"

11"

 

Maximum

.90

105

 

91

82.8

83.19

3

5"

11"

 

 

 

 

 

 

 

 

 

 

 

PFO-4

Minimum

.60

74

 

64

87.5

88.23

4

6"

14¼"

 

Maximum

1.35

159

 

138

83.3

83.91

4

6"

14¼"

 

 

 

 

 

 

 

 

 

 

 

PFO-5

Minimum

.75

93

 

81

87.5

88.23

5

6"

17½ "

 

Maximum

1.70

199

 

173

83.9

84.63

5

6"

17½ "

 

 

 

 

 

 

 

 

 

 

 

PFO-7

Minimum

1.05

130

 

113

87.6

88.24

7

7"

24"

 

Maximum

2.35

276

 

240

**

**

7

7"

24"

 

 

 

 

 

 

 

 

 

 

 

PFO-9

Minimum

1.35

167

 

146

87.6

88.26

9

8"

30½ "

 

Maximum

3.00

353

 

307

**

**

9

8"

30½ "

 

 

 

 

 

 

 

 

 

 

 

 

MODELS WITH TANKLESS COIL

 

 

 

 

RECOMMENDED

HEATING

 

NET I=B=R

ANNUAL FUEL

STEADY STATE

NO.

FLUE

LENGTH

MODEL

FIRING RATES

CAPACITY

 

RATING

UTILIZATION

"A"

 

EFFICIENCY %

SEC.

SIZE

 

GPH

 

MBH

 

MBH

EFFICIENCY%

DIMENSION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1

 

Note 2

Note 3

 

 

 

 

PFO-3T

Minimum

.50

62

 

54

87.6

88.40

3

6"

14¼"

 

Maximum

1.10

129

 

112

82.9

83.77

3

6"

14¼"

 

 

 

 

 

 

 

 

 

 

 

PFO-4T

Minimum

.65

80

 

70

87.5

88.35

4

6"

17½ "

 

Maximum

1.45

169

 

147

83.3

84.24

4

6"

17½ "

 

 

 

 

 

 

 

 

 

 

 

PFO-5T

Minimum

.80

99

 

86

87.5

88.31

5

7"

20¾ "

 

Maximum

1.75

208

 

182

83.8

84.72

5

7"

20¾ "

 

 

 

 

 

 

 

 

 

 

 

PFO-6T

Minimum

.95

117

 

102

87.5

88.26

6

7"

24"

 

Maximum

2.10

250

 

217

84.3

85.20

6

7"

24"

 

 

 

 

 

 

 

 

 

 

 

PFO-8T

Minimum

1.25

154

 

134

87.4

88.15

8

8"

30½ "

 

Maximum

2.75

324

 

282

**

**

8

8"

30½ "

 

 

 

 

 

 

 

 

 

 

 

** Capacity greater than that requiring testing under F.T.C. regulations

Firing rates of 2.00 gph or less use a Beckett Model AFG oil burner. Firing rates over 2.00 gph use a Beckett Model CF375 oil burner. Optional Riello 40 series oil burners also available. As an Energy Star Partner, Dunkirk Radiator Corporation has determined that this product meets the Energy Star guidelines for Energy Efficiency.