Rheem HG Relief Valve, To Fill the Water Heater, Condensation, Care and Cleaning Operating

Page 10

Safety Instructions

Installing the water heater.

A new combination temperature and pressure relief valve, complying with the Standard for Relief Valves and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22, is supplied and must remain in the opening provided and marked for the purpose on the water heater. No valve of any type should be installed between the relief valve and the tank. Local codes shall govern the installation of relief valves.

Relief Valve

Instructions Installation Instructions

The pressure rating of the relief valve must not exceed 150 PSI, the maximum working pressure of the water heater as marked on the rating plate.

The BTUH rating of the relief valve must equal or exceed the BTUH input of the water heater as marked on its rating plate.

Position the outlet of the relief valve above a suitable open drain to eliminate potential water damage. Piping used should be of a type approved for hot water distribution.

The discharge line must be no smaller than the outlet of the valve and must pitch downward from the valve to allow complete drainage (by gravity) of the relief valve and discharge line.

The end of the discharge line should not be threaded or concealed and should be protected from freezing. No valve of any type, restriction or reducer coupling should be installed in the discharge line.

Care and Cleaning Operating

WARNING: The tank must be full of water before heater is turned on. The water heater warranty does not cover damage or failure resulting from operation with an empty or partially empty tank.

To Fill the Water Heater

Make certain that drain valve is closed, then open the shut-off valve in the cold water supply line.

Open each hot water faucet slowly to allow the air to vent from the water heater and piping.

A steady flow of water from the hot water faucet(s) indicates a full water heater.

Customer Service Troubleshooting Tips

Condensation

Condensation can form on the tank when it is first filled with water. Condensation might also occur with a heavy water draw and very cold inlet water temperatures.

Drops of water falling on the burner can produce a sizzling or pinging sound, and the water may also be seen beneath the water heater.

This condition is not unusual, and will disappear after the water becomes heated. If, however, the condensation continues, examine the piping and fittings for possible leaks.

10

Image 10
Contents Do not try to light any appliance Manufactured under trademark license byFor Your Records If YOU Need ServiceRead this Manual Install the Draft Hood and Properly Vent the Water HEATER… N G E RLiquefied Petroleum Models Water Temperature Adjustment Read and Follow this Safety Information Carefully For Installations in the State of CaliforniaSafety Precautions Customer Service Troubleshooting Tips Installing the water heater LocationCorrosive Atmospheres Service Troubleshooting TipsCombustion and Ventilation Air Inspect ShipmentThermal Expansion Typical InstallationWater Supply Connections To Fill the Water Heater Care and Cleaning OperatingRelief Valve CondensationGas Supply Leak TestingPressure Testing the Gas Supply System High Altitude…Venting InstructionsCleaning Troubleshooting Tips Customer Service Combination Potable and Space Heating ApplicationService Troubleshooting Tips Care and Cleaning Instructions Safety InstructionsLighting the water heater Care and Cleaning Troubleshooting Tips Customer Service Safety Instructions InstallationLighting the water heater. With SmartWater Ignition System Time/Temperature Relationship in Scalds Safety PrecautionsWater Temperature Setting Operating the water heaterSafety If adjustment is necessary…Safety Range Cleaning Troubleshooting Tips CustomerDraining the Water Heater Care and cleaning of the water heaterRoutine Preventative Maintenance HousekeepingVacation and Extended Shut-Down Venting System InspectionBurner Inspection Anode RodBefore You Call For Service… Problem Possible Causes What To DoThis manual Thermostat mayInstallation Instructions Replacement PartsFor 30, 40 and 50 gallon models using natural or LP gas Instructions For Placing a Parts OrderPlease place in envelope and mail to Water Heater Model Number Serial Number Model Number Serial NumberAfter mailing