Rheem Indirect Water Heater warranty Anode rods, Temperature and pressure relief value t&P

Page 6

Section II: General Information (cont..)

anode rods

The anode rod is used as a sacrificial element within the volume of the storage tank. The purpose of the magnesium anode rod is to protect the inside of the tank against corrosion. Anode rods should be inspected twice in the first year and at least yearly once a time interval for inspection has been developed. Water conditions can influence the consumption rate of the anode rods. Please see the Maintenance section of this manual for instructions on how to change the anode rods in your Rheem indirect water heater.

CAUTION: Hydrogen gas is produced in a hot water system served by this indirect water heater that has not been used for a long period of time (2 weeks or more). Hydrogen gas is extremely flammable. To reduce the risk of injury under these conditions, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system. When hydrogen is present, there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow. There should be no smoking or open flame near the faucet at the time it is open (UL 174).

Temperature and pressure relief value (t&P)

The T&P valve is factory installed. A discharge drain tube must be installed (responsibility of the installer) and shall terminate plain, not threaded, 6 inches above the floor drain. The drain tube material must be approved for temperatures of 120°F or greater, and a pressure of 150 PSI or greater.

back-flow preventor (closed loop system)

Some local municipal codes and ordinances require the use of these devices on potable (domestic) water lines. Where back-flow preventors are required, it will be necessary to install a thermal expansion tank (designed for used with potable water) in order to prevent pressure build up in the indirect water heater and associated piping, which could cause the T&P valve to discharge. Follow the expansion tank manufacturer’s recommendations when selecting a tank for your hot water system.

NOTICE: Working pressure of the indirect water heater is 150 PSI. Do not exceed 150 PSI.

Page 6

Image 6
Contents Indirect Water Heater Table of Contents Section I Specifications NPTSTID30 Location Temperature controlSection II General Information Water treatment/filtrationTemperature and pressure relief value t&P Anode rodsBack-flow preventor closed loop system Section III Pre-Installation Boiler and circulator sizingGrundfos UP 15-42F performance curve Section IV Installation Water connectionsRheem Indirect Water Heater with Low-Mass Boiler Electrical connections Indirect CirculatorRelief valve Section V MaintenanceWater piping Flush the tankSection VI Troubleshooting 352%/0 $86 62/87,21Section VIi parts list Description Applicable ModelsLimited Warranty Exclusive Warranty Limitation of Liability