Rheem PVR50-80 (NAT) Draining the Water Heater, Routine Preventative Maintenance, Housekeeping

Page 19

Care and cleaning of the water heater.

Draining the Water Heater

!CAUTION: Shut off gas to the water heater at the gas control (thermostat) gas cock or manual shut-off valve before draining water.

!DANGER: Before manually operating the temperature and pressure relief valve, make certain no one will be exposed to the hot water released by the valve. The water drained from the tank may be hot enough to present a scald hazard and should be directed to a suitable drain to prevent injury or damage.

In order to drain the water heater, turn off the cold water supply. Open a hot water faucet or lift the handle on the relief valve to admit air to the tank.

Attach a garden hose to the drain valve on the water heater and direct the stream of water to a drain. Open the valve.

DANGER: Before manually operating the

Routine Preventative Maintenance

relief valve, make certain no one will be exposed to the danger of the hot water released by the valve. The water may be hot enough to create a scald hazard. The water should be released into a suitable drain to prevent injury or property damage.

!DANGER: Hotter water increases the potential for Hot Water Scalds.

DANGER: Failure to perform the recommended Routine Preventative Maintenance can harm the proper operation of this water heater, which can cause carbon monoxide dangers, excessive

hot water temperatures and other potentially hazardous conditions.

Properly maintained, your water heater will provide years of dependable trouble- free service.

It is recommended that a periodic inspection of the gas control (thermostat), burner, relief valve, internal flue-way and venting system should be made by service personnel qualified in gas appliance repair.

It is suggested that a routine preventative maintenance program be established and followed by the user.

At least once a year, lift and release the lever handle on the temperature pressure relief valve, located near the top of the water heater, to make certain the valve operates freely. Allow several gallons to flush through the discharge line to an open drain.

NOTICE: If the temperature and pressure relief valve on the hot water heater discharges periodically, this may be due to thermal expansion in a closed water system. Contact the water supplier or your plumbing contractor on how to correct this. DO NOT plug the relief valve outlet.

A water heater’s tank can act as a settling basin for solids suspended in the water. It is therefore not uncommon for hard water deposits to accumulate in the bottom of the tank. If allowed to accumulate, these solids can cover the gas control

(thermostat) sensors, causing the sensors to operate erratically. Because accumulated solids can prevent the gas control (thermostat) sensors from accurately reading the water temperature, the water at the fixture can be hotter than the gas control (thermostat) dial setting. It is suggested that a few quarts of water be drained from the water heater’s tank every month to clean the tank of these deposits.

Rapid closing of faucets or solenoid valves in automatic water using appliances can cause a banging noise heard in a water pipe. Strategically located risers in the water pipe system or water hammer arresting devices can be used to minimize the problem.

The anode rod should be removed from the water heater’s tank annually for inspection and replaced when more than 6” of core wire is exposed at either end of the rod.

Make sure the cold water supply is turned off before removing anode rod.

This water heater incorporates a combustion shut off device that shuts the operation of the water heater down if undesirable combustion conditions occur. Such as the presence of flammable vapors or blockage of the combustion air inlet openings. Please contact a Qualified Service Technician if this occurs.

!DANGER: Combustible materials, such as clothing, cleaning materials, or flammable liquids, etc., must not be placed against or next to the water heater.

Housekeeping

Visually inspect pilot burner and relight if necessary.

To ensure sufficient ventilation and combustion air supply, proper clearances must be maintained.

When installed in a closet, DO NOT block or obstruct any of the combustion air inlet openings located around the perimeter of the water heater. A minimum of 1” is required between these combustion air inlet

openings and any obstruction.

19

 

Image 19
Contents Water Heaters For Your Records Read the Safety InformationRead this Manual R N I N G Install the Draft Hood and Properly Vent the Water HEATER…N G E R Water Temperature SettingPage Safety Precautions For Installations in the State of CaliforniaRead and Follow this Safety Information Carefully Location Installing the water heaterCombustion and Ventilation Air Inspect ShipmentCorrosive Atmospheres Thermal Expansion Typical InstallationWater Supply Connections To Fill the Water Heater Relief ValveCondensation High Altitude Leak TestingPressure Testing the Gas Supply System Gas SupplyInsulation Blankets VentingDuring Installation of this water heater Hot and Cold Pipe Insulation InstallationHeat Trap Water Heater Location Installation ChecklistWater Supply Combination Potable and Space Heating Application Lighting the water heater Time/Temperature Relationship in Scalds Water Temperature SettingOperating the water heater Water Temperature Setting… Draining the Water Heater Routine Preventative MaintenanceHousekeeping Anode Rod Venting System InspectionBurner Inspection Vacation and Extended Shut-DownProblem Possible Causes What To Do Before You Call For Service…Rumbling noise Instructions For Placing a Parts Order Replacement PartsIf YOU Need Service

PVR50-80 (NAT) specifications

The Rheem PVR50-80 (NAT) is a premium hot water system designed for households with high demands for hot water. Known for its reliability and efficiency, this model offers a perfect blend of innovative technology and user-friendly features, making it a great choice for both residential builders and homeowners.

One of the standout features of the Rheem PVR50-80 is its 5-star energy efficiency rating, which is made possible by the unit’s advanced heating technology. This system utilizes a gas-fired water heater with a robust 80-litre storage capacity, making it an excellent option for families with varying hot water needs. With a maximum temperature of 75 degrees Celsius, it provides ample hot water for showers, baths, and household chores, ensuring that your family will never run out.

Rheem has integrated various technologies into the PVR50-80 to enhance its performance and reliability. The unit features a reliable temperature control system that allows users to set the desired water temperature accurately. This ensures consistent temperature delivery while minimizing energy consumption and waste. Additionally, the model is equipped with a durable vitreous enamel tank, which is designed to prevent corrosion and enhance the lifespan of the water heater.

The Rheem PVR50-80 also comes with an electronic ignition system that ensures easy and safe start-up every time. This feature eliminates the need for continuous pilot lighting, leading to improved energy efficiency. Moreover, the heater includes a variety of safety features, such as a temperature-pressure relief valve, which provides peace of mind for homeowners.

Another notable characteristic of this hot water system is its compact design, allowing for flexible installation in various spaces, including tight spots in homes. The unit is compatible with both natural gas and LPG systems, making it versatile for different household setups.

Rheem stands out in the market not only for producing efficient and powerful water heaters but also for their focus on quality and durability. The PVR50-80 (NAT) is backed by an extensive warranty, reflecting the manufacturer’s confidence in its product quality.

In conclusion, the Rheem PVR50-80 (NAT) is a powerful, efficient, and reliable choice for any household that requires a steady supply of hot water. With its advanced features, durable construction, and user-friendly operation, it remains a popular option in the competitive market of hot water solutions.