Rheem RS120-64BP, RS80-40BP, RS80-48BP installation instructions Installation Requirements Specific

Page 9

TABLE 1

 

LATITUDE

 

 

25°N

 

30°N

35°N

 

40°N

45°N

 

50°N

COLL. TILT

 

 

35°

 

40°

 

45°

 

50°

 

55°

 

60°

 

 

 

 

 

A

 

B

A

 

B

A

 

B

A

 

B

A

 

B

A

 

B

 

 

FLAT

29

 

96

33

 

113

37

 

145

41

 

145

44

 

145

48

 

145

 

 

 

1/12

25

 

83

29

 

93

33

 

113

37

 

132

41

 

133

44

 

141

 

 

 

2/12

22

 

74

26

 

82

30

 

77

34

 

110

38

 

115

41

 

118

 

 

14°

 

3/12

17

 

66

22

 

72

26

 

82

30

 

92

34

 

95

38

 

98

 

 

18°

 

4/12

14

 

61

18

 

66

22

 

74

26

 

82

30

 

85

34

 

87

ROOF

 

23°

 

5/12

10

 

58

14

 

60

18

 

66

22

 

72

26

 

74

30

 

77

PITCH

 

27°

 

6/12

7

 

58

11

 

58

15

 

61

19

 

66

23

 

68

27

 

70

 

 

30°

 

7/12

4

 

58

8

 

58

13

 

58

17

 

62

21

 

65

25

 

66

 

 

34°

 

8/12

0

 

58

5

 

58

9

 

58

13

 

58

17

 

60

22

 

62

 

 

37°

 

9/12

0

 

58

3

 

58

7

 

58

11

 

58

15

 

58

19

 

58

 

 

40°

 

10/12

0

 

58

0

 

58

4

 

58

8

 

58

13

 

58

17

 

58

 

 

43°

 

11/12

0

 

58

0

 

58

2

 

58

6

 

58

10

 

58

14

 

58

 

 

45°

 

12/12

0

 

58

0

 

58

0

 

58

4

 

58

8

 

58

13

 

58

 

 

 

 

 

 

 

DIMENSIONS A AND B ARE DESIGNATED IN INCHES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In order to completely protect the integrity of the solar collector and piping, the system is designed to be drained manually if subject to extended periods of disuse or persistent hard freeze conditions below minus 30° Fahrenheit. (See Sections 8.1 and 8.2 below).

3)INSTALLATION REQUIREMENTS - GENERAL

3.1The contractor shall obtain all required permits and approvals.

3.2The installation shall conform to all federal, state and local regulations, codes, ordinances and standards governing solar water heating system installations, and the contractor shall adhere to sound building safety and trade practices. Special consideration must be given to building code requirements for

the penetration of structural members and fire rated assemblies.

3.3The solar collector must be located in a structurally sound area of the roof that will be unshaded for the majority of the day all year round. Adjacent buildings and trees should be checked for possible winter shading. An instrument such as the

Pathfinder can be used for solar site analysis.

3.4Before the installation the contractor shall inspect the condition of the roof and notify the homeowner of any existing roof damage or necessary repairs.

3.5The homeowner and contractor shall confirm the location of all roof and ground mounted components in advance of the installation.

4)INSTALLATION REQUIREMENTS - SPECIFIC

4.1 Collector Orientation

The performance of solar water heating systems

fig.3

SIDE PITCH MOUNTING

9

Image 9
Contents Pumped Solar Water Heating Systems Introduction , 4 Safety Precautions Safety InformationIntroduction Try to use Hot Water during Daylight Hours Keep the use of the Backup Heater to a MinimumTime/Temperature Relationship in Scalds Water temperature settingFor Installations in the State of California Preface Staggered Mount Installation Requirements Specific Reverse Pitch Mounting Composition Shingle Mounting Shingle Roof Mounting Tile Roof Mounting Tile Roof Mounting Flush Mounting Flush Mounting Tilt Mount Stand OFF Tilt Mount Collector Collector Plumbing Vertical Mount Regular tap water as a mixing agent is prohibited Collector Plumbing Horizontal MountSingle Tank System Schematic Double Tank System Schematic Tank Sensor Electrical Components System START-UP Procedures 100% Solar Solar 100% Utility Rheem System Component Parts Tank SystemPage Rheem System Model Numbers RS80-48BP Page Page Page If YOU Need Service

RS80-40BP, RS80-48BP, RS120-64BP specifications

The Rheem RS120-64BP, RS80-48BP, and RS80-40BP are part of Rheem's innovative line of commercial water heaters, specifically designed to provide reliable, energy-efficient hot water solutions for a variety of applications. These models are distinguished by their advanced technologies, robust construction, and user-friendly features, making them ideal for businesses, institutions, and other commercial settings.

One of the standout features of the Rheem RS series is its high recovery rate. This is crucial for commercial establishments that experience high demand for hot water, ensuring that there is always an adequate supply available, even during peak usage times. The RS120-64BP, for instance, is built to deliver a rapid recovery while maintaining excellent energy efficiency, which is a significant advantage for businesses looking to reduce operational costs.

In terms of technology, the Rheem RS models are equipped with advanced electronic controls that enhance performance monitoring and management. These controls allow for precise temperature adjustments and can result in energy conservation, further reducing costs. Additionally, many models feature a built-in diagnostic system that alerts users to any potential issues before they escalate into more significant problems, ensuring uninterrupted hot water supply.

Durability is another hallmark of the Rheem RS series. Constructed with high-quality materials, these water heaters are designed to withstand the rigors of commercial use. Their robust tanks are often lined with premium materials that resist corrosion, extending the lifespan of the unit and ensuring reliability over time.

These models also offer excellent insulation, which minimizes heat loss and boosts overall efficiency. The insulation reduces energy consumption, contributing to lower utility bills and a smaller carbon footprint, which is becoming increasingly important in today’s environmentally conscious market.

The RS80-48BP and RS80-40BP are also designed with convenience in mind. They typically come with easy-to-use connection points and plumbing options that simplify installation and integration into existing systems. These features make it easier for businesses to upgrade their hot water systems without major disruptions to operations.

In summary, the Rheem RS120-64BP, RS80-48BP, and RS80-40BP are exemplary models of commercial water heaters that combine efficiency, durability, and advanced technology. With their high recovery rates, intuitive electronic controls, and robust construction, these units are tailored to meet the demanding hot water needs of any commercial environment. Businesses can trust these models to deliver reliable performance while also contributing to energy savings.