Rheem RS120-64BP, RS80-40BP, RS80-48BP installation instructions Tank Sensor

Page 24

fig.18

TANK SENSOR

Open the upper charge faucet and allow the pressure from the expansion tank to push the water in the glycol loop back to prime the pressure pump. When the hose in the bucket containing the glycol mixture stops bubbling you may begin charging the collector loop with glycol.

With both charge faucets now open, run the Flojet pressure pump until the pinkish glycol mixture begins flowing into the empty bucket. Quickly switch the hose from the empty/return bucket to the bucket containing the glycol mixture. Continue to circulate the fluid using the pressure pump until the bubbling has stopped and the air has been purged.

4.11.5After charging the collector loop, shut the lower charge faucet and let the pressure pump drive up the loop pressure to the appropriate level (Generally in the range of 25 PSI). To more accurately calculate the proper pressure measure the height of the solar collector above the solar storage tank and divide this number by 2.31. Then add 20 PSI to this number. As a word of caution, the pressure in the glycol

loop should not exceed 45 PSI when the system is

operational on a good sunny day. Contact your solar contractor if the charged collector loop pressure exceeds this threshold.

Your Rheem solar water heating system must be charged and the fluid quality maintained by an experienced contractor. If the system is drained during the winter, or you notice a significant drop in collector loop pressure, contact your installation contractor immediately for service. The glycol HTF provides the freeze protection for your system and must be properly maintained. An experienced contractor should periodically check the HTF fluid quality.

4.11.6 Dowfrost HD HTF

To ensure maximum effectiveness for corrosion protection, the glycol inhibitor package is designed for a minimum 25-30 percent concentration of glycol in water. Table 4 shows the concentrations of Dowfrost HD required to provide freeze and burst protection at various temperatures. Use the mixture most appropriate for your climate. Do not use a higher glycol to water concentration than necessary,

24

Image 24
Contents Pumped Solar Water Heating Systems Safety Information Introduction , 4 Safety PrecautionsIntroduction Keep the use of the Backup Heater to a Minimum Try to use Hot Water during Daylight HoursWater temperature setting Time/Temperature Relationship in ScaldsFor Installations in the State of California Preface Staggered Mount Installation Requirements Specific Reverse Pitch Mounting Composition Shingle Mounting Shingle Roof Mounting Tile Roof Mounting Tile Roof Mounting Flush Mounting Flush Mounting Tilt Mount Stand OFF Tilt Mount Collector Collector Plumbing Vertical Mount Collector Plumbing Horizontal Mount Regular tap water as a mixing agent is prohibitedSingle Tank System Schematic Double Tank System Schematic Tank Sensor Electrical Components System START-UP Procedures 100% Solar Solar 100% Utility Tank System Rheem System Component PartsPage Rheem System Model Numbers RS80-48BP Page Page Page If YOU Need Service

RS80-40BP, RS80-48BP, RS120-64BP specifications

The Rheem RS120-64BP, RS80-48BP, and RS80-40BP are part of Rheem's innovative line of commercial water heaters, specifically designed to provide reliable, energy-efficient hot water solutions for a variety of applications. These models are distinguished by their advanced technologies, robust construction, and user-friendly features, making them ideal for businesses, institutions, and other commercial settings.

One of the standout features of the Rheem RS series is its high recovery rate. This is crucial for commercial establishments that experience high demand for hot water, ensuring that there is always an adequate supply available, even during peak usage times. The RS120-64BP, for instance, is built to deliver a rapid recovery while maintaining excellent energy efficiency, which is a significant advantage for businesses looking to reduce operational costs.

In terms of technology, the Rheem RS models are equipped with advanced electronic controls that enhance performance monitoring and management. These controls allow for precise temperature adjustments and can result in energy conservation, further reducing costs. Additionally, many models feature a built-in diagnostic system that alerts users to any potential issues before they escalate into more significant problems, ensuring uninterrupted hot water supply.

Durability is another hallmark of the Rheem RS series. Constructed with high-quality materials, these water heaters are designed to withstand the rigors of commercial use. Their robust tanks are often lined with premium materials that resist corrosion, extending the lifespan of the unit and ensuring reliability over time.

These models also offer excellent insulation, which minimizes heat loss and boosts overall efficiency. The insulation reduces energy consumption, contributing to lower utility bills and a smaller carbon footprint, which is becoming increasingly important in today’s environmentally conscious market.

The RS80-48BP and RS80-40BP are also designed with convenience in mind. They typically come with easy-to-use connection points and plumbing options that simplify installation and integration into existing systems. These features make it easier for businesses to upgrade their hot water systems without major disruptions to operations.

In summary, the Rheem RS120-64BP, RS80-48BP, and RS80-40BP are exemplary models of commercial water heaters that combine efficiency, durability, and advanced technology. With their high recovery rates, intuitive electronic controls, and robust construction, these units are tailored to meet the demanding hot water needs of any commercial environment. Businesses can trust these models to deliver reliable performance while also contributing to energy savings.