see that they calibrate to 10K ohm resistance at 77°F. If you find a defective sensor replace it immediately. Note that in a two tank system nighttime heat loss will be harder to detect, especially if you are operating in the solar preheat mode. Check the line thermometers (No. 3) in the collector loop piping to detect night thermosiphoning.

9.10If the weather is poor and the auxiliary heating element will not fire, the bright red reset button on the thermostat may have to be depressed to be reset. Single tank systems have one heating element and thermostat. Double tank systems with conventional electric water heaters have two heating elements and thermostats (see fig 17, No. 29).

Never remove the protective access plate on the exterior of the solar storage tank or conventional water heater without disconnecting the 230 volt power supply at the circuit breaker.

After the circuit breaker has been turned off, remove the access plate on the storage tank or water heater and depress the red reset button on the thermostat. If it clicks when depressed the heating element should fire 30

immediately when you reconnect the circuit breaker. It the reset button does not click and you do not have hot water after one hour, the heating element or thermostat may be defective. Contact your installation contractor for service.

In two tank systems the conventional electric water heater will be wired for electrical back-up. The solar tank will serve solely as a storage tank and will not be wired.

10) Rheem SYSTEM COMPONENT PARTS

See Figures 16 and 17 for the location of the specific components numbered below.

1)Rheem Solar Collector(s): Absorbs the sun's heat energy and transfers this heat to the HTF circulating through the collector. (Provided)

2)Collector Sensor: Wired to the system controller. Works in conjunction with the tank sensor to automatically turn your circulating pump on and off at preset temperature differentials. (Provided)

Image 30
Contents Pumped Solar Water Heating Systems Safety Information Introduction , 4 Safety PrecautionsIntroduction Keep the use of the Backup Heater to a Minimum Try to use Hot Water during Daylight HoursWater temperature setting Time/Temperature Relationship in ScaldsFor Installations in the State of California Preface Staggered Mount Installation Requirements Specific Reverse Pitch Mounting Composition Shingle Mounting Shingle Roof Mounting Tile Roof Mounting Tile Roof Mounting Flush Mounting Flush Mounting Tilt Mount Stand OFF Tilt Mount Collector Collector Plumbing Vertical Mount Collector Plumbing Horizontal Mount Regular tap water as a mixing agent is prohibitedSingle Tank System Schematic Double Tank System Schematic Tank Sensor Electrical Components System START-UP Procedures 100% Solar Solar 100% Utility Tank System Rheem System Component PartsPage Rheem System Model Numbers RS80-48BP Page Page Page If YOU Need Service

RS80-40BP, RS80-48BP, RS120-64BP specifications

The Rheem RS120-64BP, RS80-48BP, and RS80-40BP are part of Rheem's innovative line of commercial water heaters, specifically designed to provide reliable, energy-efficient hot water solutions for a variety of applications. These models are distinguished by their advanced technologies, robust construction, and user-friendly features, making them ideal for businesses, institutions, and other commercial settings.

One of the standout features of the Rheem RS series is its high recovery rate. This is crucial for commercial establishments that experience high demand for hot water, ensuring that there is always an adequate supply available, even during peak usage times. The RS120-64BP, for instance, is built to deliver a rapid recovery while maintaining excellent energy efficiency, which is a significant advantage for businesses looking to reduce operational costs.

In terms of technology, the Rheem RS models are equipped with advanced electronic controls that enhance performance monitoring and management. These controls allow for precise temperature adjustments and can result in energy conservation, further reducing costs. Additionally, many models feature a built-in diagnostic system that alerts users to any potential issues before they escalate into more significant problems, ensuring uninterrupted hot water supply.

Durability is another hallmark of the Rheem RS series. Constructed with high-quality materials, these water heaters are designed to withstand the rigors of commercial use. Their robust tanks are often lined with premium materials that resist corrosion, extending the lifespan of the unit and ensuring reliability over time.

These models also offer excellent insulation, which minimizes heat loss and boosts overall efficiency. The insulation reduces energy consumption, contributing to lower utility bills and a smaller carbon footprint, which is becoming increasingly important in today’s environmentally conscious market.

The RS80-48BP and RS80-40BP are also designed with convenience in mind. They typically come with easy-to-use connection points and plumbing options that simplify installation and integration into existing systems. These features make it easier for businesses to upgrade their hot water systems without major disruptions to operations.

In summary, the Rheem RS120-64BP, RS80-48BP, and RS80-40BP are exemplary models of commercial water heaters that combine efficiency, durability, and advanced technology. With their high recovery rates, intuitive electronic controls, and robust construction, these units are tailored to meet the demanding hot water needs of any commercial environment. Businesses can trust these models to deliver reliable performance while also contributing to energy savings.