MODEL NUMBERS

 

IMMERSION THERMOSTATS

 

 

INPUT

Tank Capacity In Gallons

 

 

KW

 

 

 

 

 

50 Gal. (190L)

85 Gal. (321L)

120 Gal. (454L)

 

6

 

 

 

 

 

9

EG50-C-9

EG85-C-9

 

EG120-C-9

 

12

EG50-C-12

EG85-C-12

 

EG120-C-12

 

15

EG50-C-15

EG85-C-15

 

EG120-C-15

 

18

EG50-C-18

EG85-C-18

 

EG120-C-18

 

24

EG50-C-24

EG85-C-24

 

EG120-C-24

 

30

EG50-C-30

EG85-C-30

 

EG120-C-30

 

36

EG50-C-36

EG85-C-36

 

EG120-C-36

 

45

 

EG85-C-45

 

EG120-C-45

 

54

 

EG85-C-54

 

EG120-C-54

ELECTRICAL CHARACTERISTICS

 

 

ELE-

FULL LOAD CURRENT

 

 

 

 

IMMERSION THERMOSTATS

 

NO.

 

IN AMPERES

Number

Number

 

 

Optional Models – Staged

INPUT

OF

MENT

208V

240V

600V

of Fuses

of

 

Number

 

Models with Suffix “F”

KW

ELE-

WAT-

 

 

 

30A Class G

Contactors

of

 

 

 

Phase

Phase

Phase

 

 

 

 

Number of

KW Step

 

MENTS

TAGE

1

3

1

3

3

208/240V

600V

208/240V

600V

Thermostats

 

 

 

 

 

Thermostats

Size

6

 

 

 

 

 

 

 

 

 

 

 

1

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

3

3000

43

25

38

22

9

6

3

2

1

1

 

9

 

ONE

12

3

4000

58

33

50

29

12

6

3

2

1

1

 

12

 

THERMOSTAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

3

5000

72

42

63

36

15

6

3

2

1

1

 

15

 

STANDARD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

3

6000

87

50

75

43

18

6

3

2

1

1

 

18

 

 

 

 

24

6

4000

116

67

100

58

23

12

6

4

2

1

2

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

6

5000

144

84

125

73

29

12

6

4

2

1

2

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36

6

6000

173

100

150

87

35

12

6

4

2

1

2

18

45

9

5000

217

125

188

109

43

18

9

6

3

1

3

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

54

9

6000

260

150

225

130

52

18

9

6

3

1

3

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOVERY CAPACITIES

Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises

 

INPUT

EQUIVALENT

 

40°F

50°F

60°F

70°F

80°F

90°F

100°F

110°F

120°F

130°F

140°F

 

KW

BTU/HR.

UNITS

(22°C)

(28°C)

(33°C)

(39°C)

(45°C)

(50°C)

(56°C)

(61°C)

(67°C)

(72°C)

(78°C)

 

6

 

GPH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LPH

 

 

 

 

 

 

 

 

 

 

 

 

9

30,709

GPH

93

74

62

53

47

41

37

34

31

29

27

 

 

 

 

LPH

352

282

235

201

176

157

141

128

117

108

101

 

12

40,946

GPH

124

99

83

71

62

55

50

45

41

38

35

 

 

 

 

LPH

470

376

313

268

235

209

188

171

157

145

134

 

15

51,183

GPH

155

124

103

89

78

69

62

56

52

48

44

 

 

 

 

LPH

587

470

391

335

294

261

235

213

196

181

168

 

18

61,420

GPH

186

149

124

106

93

83

74

68

62

57

53

 

 

 

 

LPH

705

564

470

403

352

313

282

256

235

217

201

 

24

81,893

GPH

248

199

165

142

124

110

99

90

83

76

71

 

 

 

 

LPH

939

751

626

537

470

417

376

342

313

289

268

 

30

102,366

GPH

310

248

207

177

155

138

124

113

103

95

89

 

 

 

 

LPH

1174

939

783

671

587

522

470

427

391

361

335

 

36

122,839

GPH

372

298

248

213

186

165

149

135

124

115

106

 

 

 

 

LPH

1409

1127

939

805

705

626

564

512

470

434

403

 

45

153,549

GPH

465

372

310

266

233

207

186

169

155

143

133

 

 

 

 

LPH

1761

1409

1174

1006

881

783

705

640

587

542

503

 

54

184,259

GPH

558

447

372

319

279

248

223

203

186

172

160

 

 

 

 

LPH

2114

1691

1409

1208

1057

939

845

769

705

650

604

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 2
Contents Construction Features Certifications and RatingsModel Numbers Electrical CharacteristicsRecovery Capacities Gal LAutomatic Temperature Control Dimensional InformationAdditional Construction Features All dimensions shown in English and MetricSample Specifications for trade reference only Three Year Limited Warranty

54 KW, 6 KW specifications

Rheem, a prominent name in the water heating industry, offers a diverse range of solutions tailored to meet the needs of both residential and commercial applications. Among its distinguished lineup are the Rheem 6 KW and 54 KW electric water heaters, which embody innovation, efficiency, and superior performance.

The Rheem 6 KW model is primarily designed for smaller households or locations requiring limited hot water supply. Its compact design makes it an excellent choice for residential installations such as apartments or utility rooms. This unit boasts features like a user-friendly digital display, which allows users to easily monitor and adjust their water temperature settings. Additionally, the 6 KW model incorporates advanced safety features, including over-temperature protection and a safety shut-off valve, ensuring peace of mind for users.

On the other hand, the Rheem 54 KW model is tailored for larger applications, including commercial settings and larger residential households with significant hot water demands. It provides a robust output, allowing for simultaneous use across multiple fixtures, making it an ideal solution for restaurants, hotels, and high-demand homes. The 54 KW heater is equipped with multiple heating elements, which enable faster recovery rates, ensuring an ample supply of hot water even during peak usage times.

Both models employ Rheem's innovative technologies aimed at enhancing energy efficiency. The use of advanced insulation materials minimizes heat loss, while the implementation of energy-efficient heating elements ensures optimal performance. Rheem electric water heaters are also designed to exceed the energy efficiency standards set by regulatory bodies, translating to lower energy bills for consumers.

Moreover, the Rheem 6 KW and 54 KW units feature a responsive temperature control system, allowing for precise adjustments to water temperature according to user preferences. Their durability is another standout characteristic, with high-quality materials selected for long-lasting performance, complemented by warranties that provide additional assurance.

In conclusion, Rheem 6 KW and 54 KW electric water heaters represent a spectrum of solutions to cater to varying hot water needs. With advanced technologies, safety features, and energy efficiency at the forefront, these models exemplify Rheem's commitment to delivering reliable and sustainable water heating solutions for consumers worldwide.