Desa GWP10 GWN10T Inspecting Heater, Thermostat Control Operation, Manual Lighting Procedure

Page 14

OPERATING HEATER

Continued

THERMOSTAT CONTROL

OPERATION

The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between 1 and 5. This adjusts the amount of gas flow to the burner that increases or decreases the burner flame height. Note: The thermostat sensing bulb measures the temperature of air near the heater cabinet. This may not always agree with room tem- perature (depending on housing construction, installation location, room size, open air tem- peratures, etc.) Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 10, page 9).

2.Follow steps 1 through 7 under Lighting Instructions, page 13.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 9, under Lighting Instructions, page 13.

5.Replace front panel.

INSPECTING HEATER

Check pilot flame pattern and burner flame pat- tern often.

PILOT FLAME PATTERN

Figure 20 shows a correct pilot flame pattern. Figure 21 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 21

• turn heater off (see To Turn Off Gas to Appli- ance, page 13)

• see Troubleshooting, page 16

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Blue Flame

Pilot Burner

Thermocouple

Figure 20 - Correct Pilot Flame Pattern

 

Yellow Flame

Thermocouple

Pilot Burner

 

Figure 21 - Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

Figure 22, page 15, shows a correct burner flame pattern. Figure 23, page 15, shows an incorrect burner flame pattern. The incorrect burner flame pat- tern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.

WARNING: If yellow tipping occurs, your heater could pro- duce increased levels of car- bon monoxide. If burner flame pattern shows yellow tipping, proceed with the following in- structions.

NOTICE: Do not mistake orange flames with yellow tipping. Dust or other fine particles enter the heater and burn causing brief patches of orange flame.

If burner flame pattern is incorrect, as shown in Figure 23, page 15,

turn heater off (see To Turn Off Gas to Appli- ance, page 13)

see Troubleshooting, page 16

14

www.desatech.com

117001-01A

Image 14
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Identification Product FeaturesLocal Codes UnpackingUnusually Tight Construction AIR for Combustion VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingCheck GAS Type AIR for Combustion Ventilation InstallationInstallation Items Ventilation Air From OutdoorsMarking Screw Locations Installing Heater to WallLocating Heater Removing Front Panel Of Heater Placing Heater On Mounting ScrewsAttaching to wall anchor method Connecting to GAS Supply Installing Bottom Mounting ScrewNatural Gas Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Propane/LPTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa For Your Safety Read Before LightingOperating Heater Lighting Instructions Ignitor Button Control KnobThermostat Control Operation Manual Lighting ProcedureInspecting Heater Pilot Flame PatternBurner Pilot AIR Inlet Cleaning MaintenanceODS/PILOT and Burner CabinetTroubleshooting Observed Problem Possible Cause RemedyODS/pilot lights but flame Yellow flame during burner Not enough air Heater produces unwanted Gas leak. See WarningIllustrated Parts Breakdown Models GWP6, GWN6, GWP10 and GWN10Parts List NJF-8CModels GWP10T and GWN10T NJF 8C Specifications Technical Service AccessoriesService Hints Service Publications Replacement PartsParts Central 117001-01A Warranty Information Keep this Warranty

GWP10 GWN10T specifications

The Desa GWP10 and GWN10T are innovative heating solutions designed for both residential and commercial applications. These models stand out in the market due to their modern features, advanced technologies, and exceptional performance characteristics.

One of the main features of the Desa GWP10 is its high efficiency. With an impressive energy efficiency rating, this model utilizes a state-of-the-art combustion system that maximizes heat output while minimizing fuel consumption. This not only reduces the cost of operation but also makes it an environmentally friendly choice, lowering carbon emissions significantly.

The GWN10T model complements the GWP10 with its advanced technology. It incorporates a sophisticated control system that allows for precise temperature regulation. Users can easily adjust the settings via a user-friendly interface, ensuring optimal comfort throughout the space it heats. The control system can also include smart functionalities, enabling remote access and monitoring through mobile applications. This level of connectivity gives users unparalleled control over their heating solutions.

Another characteristic that sets both models apart is their build quality. Designed to endure harsh conditions, the Desa GWP10 and GWN10T feature durable materials and robust construction. This ensures longevity and reliability, making them suitable for long-term use in various environments. Additionally, both models come with enhanced safety features, including automatic shut-off mechanisms and overheat protection, providing peace of mind to users.

Moreover, ease of installation is a key aspect of the Desa heating solutions. The GWP10 and GWN10T are designed to be easily integrated into existing heating systems or as standalone units. The compact designs allow for versatile placement, making them ideal for different room layouts and building configurations.

In summary, the Desa GWP10 and GWN10T are sophisticated heating systems that combine efficiency, advanced technologies, and robust design. With high energy efficiency ratings, smart control options, and a focus on safety and reliability, these models cater to the modern consumer's needs for comfort and convenience in heating solutions. Whether for residential or commercial use, the Desa GWP10 and GWN10T are excellent choices for anyone seeking effective and innovative heating technology.