This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual.

KEY

 

 

GWP10T

NO.

PART NO.

DESCRIPTION

 

1

098304-01

Screw, #10 x 3/8"

2

099467-07

Front Panel Assembly

3

099318-04

Grill Guard

4

101108-01

Grill Guard Clip

5 102017-02 Bottom Glass Retainer

6

098260-11

Glass Panel

7

099319-02

Top Glass Retainer

8

099317-02

Deflector Unit

9

098271-09

Ignitor Cable

10

098249-01

Nut, M5

11

110803-01*

ODS/Pilot Assembly

 

 

110803-02*

ODS/Pilot Assembly

11-1 110186-01

Thermocouple Kit

12

104263-03

Burner

13

099387-11

Pilot Tubing

14

104259-05

Injector, 1 Piece

 

 

104259-06

Injector, 1 Piece

15

NJF 8C

Hex Nut

16

099415-17

Pressure Regulator

 

 

099415-18

Pressure Regulator

17

104261-01

Burner Tubing

18

104264-01

Regulator Tubing

19

098522-11

Thermostat Gas Valve

 

 

098522-18

Thermostat Gas Valve

20

**

Cabinet Assembly

21

097159-04

Piezo Ignitor

PARTS AVAILABLE - NOT SHOWN

GWN10T

QTY.

2

1

1

2

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

100642-02 Assembly, Hardware

• • 1

** Not a field replaceable part.

 

*If replacing ODS pilot and your model is pre 2002, your part number will be 100701-03 for natural gas models, 099059-03 for propane/LP models. The thermocouple part number will be 098514-01 for both gases. The electrode part number will be 098594-01 for both gases.

117001-01A

www.desatech.com

23

Image 23
Contents What to do if YOU Smell GAS Table of Contents Safety Information Unpacking Product FeaturesLocal Codes Product IdentificationConfined and Unconfined Space AIR for Combustion VentilationProviding Adequate Ventilation Unusually Tight ConstructionVentilation Air From Inside Building Determining FRESH-AIR Flow for Heater LocationVentilation AIR Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors AIR for Combustion Ventilation InstallationInstallation Items Check GAS TypeMarking Screw Locations Installing Heater to WallLocating Heater Removing Front Panel Of Heater Placing Heater On Mounting ScrewsAttaching to wall anchor method Installing Bottom Mounting Screw Connecting to GAS SupplyPropane/LP Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Natural GasTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa For Your Safety Read Before LightingOperating Heater Ignitor Button Control Knob Lighting InstructionsPilot Flame Pattern Manual Lighting ProcedureInspecting Heater Thermostat Control OperationCabinet Cleaning MaintenanceODS/PILOT and Burner Burner Pilot AIR InletObserved Problem Possible Cause Remedy TroubleshootingODS/pilot lights but flame Yellow flame during burner Not enough air Gas leak. See Warning Heater produces unwantedModels GWP6, GWN6, GWP10 and GWN10 Illustrated Parts BreakdownNJF-8C Parts ListModels GWP10T and GWN10T NJF 8C Specifications Service Publications Replacement Parts AccessoriesService Hints Technical ServiceParts Central 117001-01A Keep this Warranty Warranty Information

GWP10 GWN10T specifications

The Desa GWP10 and GWN10T are innovative heating solutions designed for both residential and commercial applications. These models stand out in the market due to their modern features, advanced technologies, and exceptional performance characteristics.

One of the main features of the Desa GWP10 is its high efficiency. With an impressive energy efficiency rating, this model utilizes a state-of-the-art combustion system that maximizes heat output while minimizing fuel consumption. This not only reduces the cost of operation but also makes it an environmentally friendly choice, lowering carbon emissions significantly.

The GWN10T model complements the GWP10 with its advanced technology. It incorporates a sophisticated control system that allows for precise temperature regulation. Users can easily adjust the settings via a user-friendly interface, ensuring optimal comfort throughout the space it heats. The control system can also include smart functionalities, enabling remote access and monitoring through mobile applications. This level of connectivity gives users unparalleled control over their heating solutions.

Another characteristic that sets both models apart is their build quality. Designed to endure harsh conditions, the Desa GWP10 and GWN10T feature durable materials and robust construction. This ensures longevity and reliability, making them suitable for long-term use in various environments. Additionally, both models come with enhanced safety features, including automatic shut-off mechanisms and overheat protection, providing peace of mind to users.

Moreover, ease of installation is a key aspect of the Desa heating solutions. The GWP10 and GWN10T are designed to be easily integrated into existing heating systems or as standalone units. The compact designs allow for versatile placement, making them ideal for different room layouts and building configurations.

In summary, the Desa GWP10 and GWN10T are sophisticated heating systems that combine efficiency, advanced technologies, and robust design. With high energy efficiency ratings, smart control options, and a focus on safety and reliability, these models cater to the modern consumer's needs for comfort and convenience in heating solutions. Whether for residential or commercial use, the Desa GWP10 and GWN10T are excellent choices for anyone seeking effective and innovative heating technology.