Desa GWP10 GWN10T installation manual Parts List, NJF-8C

Page 21

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual.

KEY

 

 

GWP6

GWN6

NO.

PART NO.

DESCRIPTION

 

 

1

098304-01

Screw, #10 x 3/8"

2

099467-07

Front Panel

3

099318-04

Grill Guard

4

101108-01

Grill Guard Clip

5

102017-02

Bottom Glass Retainer

6

098260-11

Glass Panel

7

099319-02

Top Glass Retainer

8

099317-02

Deflector Unit

9

098271-09

Ignitor Cable

10

098249-01

Nut, M5

11

110803-01*

ODS/Pilot Assembly

 

 

110803-02*

ODS/Pilot Assembly

 

11-1

110186-01

Thermocouple Kit

12

104263-03

Burner

 

 

104263-02

Burner

 

13

099387-17

Pilot Tubing

14

104259-01

Injector, 1 piece

 

 

 

104259-02

Injector, 1 piece

 

 

 

104259-03

Injector, 1 piece

 

 

104259-04

Injector, 1 piece

 

15

NJF-8C

Hex Nut

16

099415-17

Pressure Regulator

 

 

099415-18

Pressure Regulator

 

17

099462-01

Burner Tubing

18

099391-02

Regulator Tubing

19

099413-01

Control Valve

 

 

099413-02

Control Valve

 

20

**

Cabinet Assembly

21

097159-04

Piezo Ignitor

22

099393-02

Control Knob

23

098508-01

Valve Retainer Nut

24

099818-01

Internal Tooth Washer

PARTS AVAILABLE - NOT SHOWN

GWP10

GWN10

QTY

2

1

1

2

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

100642-02 Assembly, Hardware

• • • • 1

** Not a field replaceable part.

 

*If replacing ODS pilot and your model is pre 2002, your part number will be 100701-03 for natural gas models, 099059-03 for propane/LP models. The thermocouple part number will be 098514-01 for both gases. The electrode part number will be 098594-01 for both gases.

117001-01A

www.desatech.com

21

Image 21
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes Product FeaturesProduct Identification UnpackingProviding Adequate Ventilation AIR for Combustion VentilationUnusually Tight Construction Confined and Unconfined SpaceVentilation AIR Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside BuildingInstallation Items AIR for Combustion Ventilation InstallationCheck GAS Type Ventilation Air From OutdoorsInstalling Heater to Wall Locating HeaterMarking Screw Locations Placing Heater On Mounting Screws Attaching to wall anchor methodRemoving Front Panel Of Heater Installing Bottom Mounting Screw Connecting to GAS SupplyTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsNatural Gas Propane/LPFor Your Safety Read Before Lighting Operating HeaterTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Ignitor Button Control Knob Lighting InstructionsInspecting Heater Manual Lighting ProcedureThermostat Control Operation Pilot Flame PatternODS/PILOT and Burner Cleaning MaintenanceBurner Pilot AIR Inlet CabinetObserved Problem Possible Cause Remedy TroubleshootingODS/pilot lights but flame Yellow flame during burner Not enough air Gas leak. See Warning Heater produces unwantedModels GWP6, GWN6, GWP10 and GWN10 Illustrated Parts BreakdownNJF-8C Parts ListModels GWP10T and GWN10T NJF 8C Specifications Service Hints AccessoriesTechnical Service Service Publications Replacement PartsParts Central 117001-01A Keep this Warranty Warranty Information

GWP10 GWN10T specifications

The Desa GWP10 and GWN10T are innovative heating solutions designed for both residential and commercial applications. These models stand out in the market due to their modern features, advanced technologies, and exceptional performance characteristics.

One of the main features of the Desa GWP10 is its high efficiency. With an impressive energy efficiency rating, this model utilizes a state-of-the-art combustion system that maximizes heat output while minimizing fuel consumption. This not only reduces the cost of operation but also makes it an environmentally friendly choice, lowering carbon emissions significantly.

The GWN10T model complements the GWP10 with its advanced technology. It incorporates a sophisticated control system that allows for precise temperature regulation. Users can easily adjust the settings via a user-friendly interface, ensuring optimal comfort throughout the space it heats. The control system can also include smart functionalities, enabling remote access and monitoring through mobile applications. This level of connectivity gives users unparalleled control over their heating solutions.

Another characteristic that sets both models apart is their build quality. Designed to endure harsh conditions, the Desa GWP10 and GWN10T feature durable materials and robust construction. This ensures longevity and reliability, making them suitable for long-term use in various environments. Additionally, both models come with enhanced safety features, including automatic shut-off mechanisms and overheat protection, providing peace of mind to users.

Moreover, ease of installation is a key aspect of the Desa heating solutions. The GWP10 and GWN10T are designed to be easily integrated into existing heating systems or as standalone units. The compact designs allow for versatile placement, making them ideal for different room layouts and building configurations.

In summary, the Desa GWP10 and GWN10T are sophisticated heating systems that combine efficiency, advanced technologies, and robust design. With high energy efficiency ratings, smart control options, and a focus on safety and reliability, these models cater to the modern consumer's needs for comfort and convenience in heating solutions. Whether for residential or commercial use, the Desa GWP10 and GWN10T are excellent choices for anyone seeking effective and innovative heating technology.