Desa FVF18P, FVF30P, FVF24P Installing Logs, Installing Heat Majic One- Piece Log Set

Page 14

FIREPLACE MANUFACTURERS INCORPORATED

UNVENTED PROPANE/LP GAS LOG HEATER

INSTALLATION

Continued

INSTALLING LOGS

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, re- position logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place one-piece log set on grate to fit as illustrated in Figure 17. Make sure bottom of front log is in front of “U”- shaped cutout in center of chassis (see Figure 17).

IMPORTANT: Make sure log does not cover any burner ports.

2.Place lava rock on fireplace floor around base of heater.

One Piece

Log Set

Burner

Chassis

"U"-shaped

Cutout in

Chassis

Figure 17 - Installing Heat Majic™ One- Piece Log Set

Burner

One Piece

ports

Log Set

Figure 18 - Installing Heat Majic™ One- Piece Log Set (Top View)

14

105192

Image 14
Contents Patent Pending OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Safety Information Local Codes Product FeaturesProduct Identification UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Building Ventilation AIRVentilation Air From Inside Ventilation Air From OutdoorsCheck GAS Type InstallationInstallation Minimum Wall and Ceiling Clearances see FigureMinimum Noncombustible Material Clearances If Using MantelIf Not Using Mantel Floor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceChimney Minimum Permanent Height ft Flue Opening sq. ins Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items Needed Attaching Flexible Gas Hose to Heater Gas RegulatorConnecting to GAS Supply A. Design-Certified Manual Shutoff Valve With 1/8 NPT TapChecking GAS Connections Pressure Testing Heater Gas ConnectionsPressure Testing Gas Supply Piping System Test Pressures Equal To or Less Than 1/2 PsigInstalling Logs Installing Heat Majic One- Piece Log SetLighting Instructions For Your Safety Read Before LightingOperating Heater Inspecting Burners Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Gas leak. See Warning statement atTechnical Service Cleaning and MaintenanceService Hints Cleaning Burner Injector Holder and Pilot AIR Inlet HoleSpecifications AccessoriesReplacement Parts ODS Pilot Illustrated Parts BreakdownHeat Majic FVF18P FVF24P FVF30P Parts List FVF18P FVF24P FVF30PWarranty Information

FVF30P, FVF18P, FVF24P specifications

Desa FVF24P, FVF18P, and FVF30P are innovative products in the heating and ventilation sector, designed to meet diverse customer needs while optimizing performance. Each model has unique features and technologies that cater to various applications whether residential, commercial, or industrial.

Starting with the FVF24P, this model is renowned for its high efficiency and compact design. It is equipped with advanced modulation technology which allows the unit to adjust its output based on real-time demand. This results in reduced energy consumption and lower operating costs. The FVF24P also boasts an integrated smart control system that enables users to monitor and manage settings remotely via smartphone applications. This feature not only enhances convenience but also maximizes comfort by ensuring optimal temperature levels at all times.

Moving on to the FVF18P, this model is specifically engineered for smaller spaces or apartments where heating efficiency is paramount without compromising on space. It incorporates a unique heat exchanger that significantly increases heat transfer efficiency. Additionally, the FVF18P features a quiet operation mode, making it suitable for bedrooms or any noise-sensitive environments. Its compact size does not detract from its performance, as it offers a balanced air distribution system ensuring every corner receives adequate warmth.

The FVF30P, on the other hand, is a powerhouse designed for larger areas requiring robust heating capabilities. It supports a wider range of airflow settings and has an impressive BTU rating, making it ideal for vast commercial spaces or industrial applications. The inclusion of multiple safety features, such as overheat protection and automatic shut-off, underscores its design philosophy focused on user safety and reliability. Furthermore, the FVF30P is built to work with renewable energy sources, aligning with modern sustainability goals and reducing the environmental impact associated with traditional heating solutions.

In summary, the Desa FVF series presents a range of efficient heating solutions with the FVF24P, FVF18P, and FVF30P models catering to different power requirements and space constraints. With advanced technologies such as smart controls, enhanced heat exchangers, and safety features, these models are a testament to Desa’s commitment to quality, efficiency, and customer satisfaction in the heating market.