Desa GVC35NA installation manual OWNER’S Operation and Installation Manual, For Your Safety

Page 1

®

VENTED NATURAL

GAS HEATERS

OWNER’S OPERATION AND INSTALLATION MANUAL

Models: GVC65NA, GVC50NA, GVC35NA

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, per- sonal injury, or loss of life.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be per- formed by a qualified installer, service agency, or the gas supplier.

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury or loss of life. Refer to this manual for cor- rect installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.

®

Save this manual for future reference.

Image 1
Contents For Your Safety OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Contents Carbon monoxide poisoning may lead to death Safety InformationSafety Information Product Identification Installation Items Local Codes Unpacking Product FeaturesCheck GAS Type Heater Clearances Locating HeaterVenting Heater Do not vent heater in any of the following ways see Figure Venting HeaterVenting Heater Proper Size Vent Connecting Heater to Utility Gas Line Connecting to GAS SupplyGas Connection Checking GAS Connections Pressure Testing Gas Supply Piping SystemFresh AIR for Combustion and Ventilation Draft Hood Spillage Test Determining FRESH-AIR Flow for Heater LocationVentilation Air from Outdoors Example 2 Locating Heater in Confined Closed Area Operating Heater For Your Safety Read Before LightingLighting Instructions Viewing Pilot Blower Operation Manual Lighting ProcedureTo Turn OFF GAS to Appliance Shutting Off HeaterPilot Flame Pattern Inspecting Pilot and Burner FlameBurner Flame Pattern Correct Burner Flame Pattern Cleaning and Maintenance Observed Possible Problem Cause Remedy Trouble ShootingTROUBLE- Shooting Cleaning and MainteLighting Instructions Top Ing statement atRemoving Control Valve and Burner Tube Service ProceduresRemoving Burner Diagram Blower WiringChanging Burner Orifice Service Hints Accessories Technical Service35,000 BTU/Hr 50,000 BTU/Hr ModelParts Under Warranty Ordering Replacement Parts CentralsParts Not Under Warranty Cabinet Assembly Illustrated Parts ListBurner Assembly Parts List Limited Warranty Vanguard Vented Natural GAS Heaters Warranty Information

GVC35NA, GVC50NA, GVC65NA specifications

Desa GVC series heaters, including models GVC35NA, GVC65NA, and GVC50NA, are prominent products in the realm of gas-fired heating solutions. These heaters are designed for residential and light commercial applications, providing a reliable heat source with high efficiency.

The GVC35NA has a heating capacity of 35,000 BTU, making it an excellent choice for smaller spaces. It features a compact design, allowing for easy installation in various settings. The advanced vent-free technology incorporated into the GVC35NA enables it to operate without the need for external venting, maximizing efficiency and eliminating heat loss. Additionally, this model includes an oxygen depletion sensor (ODS), which ensures safety by shutting off the unit if oxygen levels drop below a certain threshold.

Moving on to the GVC50NA, this model provides a mid-range heating capacity of 50,000 BTU. This unit is ideal for medium-sized rooms and offers the same vent-free technology as the GVC35NA. The GVC50NA's unique design also enhances airflow, ensuring a consistent and comfortable temperature throughout the space. Like its counterpart, it is equipped with the ODS for added safety, making it suitable for use in bedrooms and other enclosed areas.

The GVC65NA represents the upper end of the GVC series, boasting a robust heating capacity of 65,000 BTU. Designed for larger spaces, it features multiple heat settings, allowing users to customize their heating experience based on specific needs. The unit’s sleek design not only provides aesthetic value but also incorporates a built-in blower option, enhancing air circulation and ensuring even heat distribution. Safety remains a priority with the GVC65NA, which includes an ODS as well as a built-in thermostat for precise temperature control.

All models in the GVC series come equipped with simple control mechanisms, ensuring ease of use. They also utilize glowing ceramic elements for efficient and effective heating. Furthermore, the stylish exterior and compact design of these heaters make them an attractive addition to any room.

In summary, the Desa GVC35NA, GVC65NA, and GVC50NA heaters provide a comprehensive range of heating solutions, combining efficiency, safety, and ease of use. Their vent-free operation, built-in safety features, and aesthetic designs make them ideal choices for a variety of heating needs. Whether for small, medium, or large spaces, there is a GVC model to meet specific requirements, ensuring comfort and warmth for users.