Desa GVC65NA, GVC50NA, GVC35NA installation manual Venting Heater

Page 8

INSTALLING HEATER

Continued

8

VENTING HEATER

Note: Venting/chimney materials are not supplied with heater.

WARNING

A qualified service person must install the venting system for this heater. If venting system is not properly installed and maintained, the vent safety shut-off system will pre- vent the heater from running. Follow all local codes.

WARNING

This heater has a vent safety shut-off system. This system shuts off the heater gas supply if you do not vent heater properly or the venting system is blocked. Do not operate heater if not properly vented. Do not tamper with the vent safety shut-off system. Carbon monoxide poisoning and death may result.

WARNING

When venting this heater, follow the safety information listed below.

Never vent heater to another room or inside a build- ing. Only vent heater to the outdoors.

Do not vent heater exhaust to a chimney or flue serving another solid-fuel-burning or gas appliance.

We recommend you use flues classified as prefabri- cated or masonry all-fuel chimney or type-B vent. See Vent Types, page 10.

If using old vent, check vent for soot, creosote, and loose particles. If vent is damaged, repair or replace it before using heater.

Extend the vertical section of vent pipe at least three feet above roof penetration.

Extend the vertical section of vent pipe at least two feet above the highest point of any roof within ten feet.

The horizontal run of vent pipe should rise at least 1/4 inch for each foot of run.

Support the vent pipe at least every five feet along its length. Do not use combustible materials to support vent pipe.

Never extend vent pipe horizontally through outside wall and terminate. You must connect a vertical run of vent pipe to the horizontal run. The vertical run must be at least 25% longer than the horizontal run.

Install vent or chimney cap that is approved for use with vented gas room heaters.

Do not use vent pipe smaller in diameter than that of the heater draft hood outlet.

Do not use dampers in the vent pipes.

Vertical height of vent must be greater than five feet above vent connection at draft hood.

100749

Image 8
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Safety Information Carbon monoxide poisoning may lead to deathSafety Information Product Identification Check GAS Type Local Codes Unpacking Product FeaturesInstallation Items Locating Heater Heater ClearancesVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Connecting to GAS Supply Connecting Heater to Utility Gas LineGas Connection Pressure Testing Gas Supply Piping System Checking GAS ConnectionsFresh AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location Draft Hood Spillage TestVentilation Air from Outdoors Example 2 Locating Heater in Confined Closed Area Lighting Instructions For Your Safety Read Before LightingOperating Heater Viewing Pilot Manual Lighting Procedure Blower OperationTo Turn OFF GAS to Appliance Shutting Off HeaterBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Correct Burner Flame Pattern Cleaning and Maintenance Trouble Shooting Observed Possible Problem Cause RemedyCleaning and Mainte TROUBLE- ShootingLighting Instructions Ing statement at TopService Procedures Removing Control Valve and Burner TubeRemoving Burner Changing Burner Orifice Blower WiringDiagram Technical Service Service Hints Accessories35,000 BTU/Hr 50,000 BTU/Hr ModelParts Not Under Warranty Ordering Replacement Parts CentralsParts Under Warranty Illustrated Parts List Cabinet AssemblyBurner Assembly Parts List Warranty Information Limited Warranty Vanguard Vented Natural GAS Heaters

GVC35NA, GVC50NA, GVC65NA specifications

Desa GVC series heaters, including models GVC35NA, GVC65NA, and GVC50NA, are prominent products in the realm of gas-fired heating solutions. These heaters are designed for residential and light commercial applications, providing a reliable heat source with high efficiency.

The GVC35NA has a heating capacity of 35,000 BTU, making it an excellent choice for smaller spaces. It features a compact design, allowing for easy installation in various settings. The advanced vent-free technology incorporated into the GVC35NA enables it to operate without the need for external venting, maximizing efficiency and eliminating heat loss. Additionally, this model includes an oxygen depletion sensor (ODS), which ensures safety by shutting off the unit if oxygen levels drop below a certain threshold.

Moving on to the GVC50NA, this model provides a mid-range heating capacity of 50,000 BTU. This unit is ideal for medium-sized rooms and offers the same vent-free technology as the GVC35NA. The GVC50NA's unique design also enhances airflow, ensuring a consistent and comfortable temperature throughout the space. Like its counterpart, it is equipped with the ODS for added safety, making it suitable for use in bedrooms and other enclosed areas.

The GVC65NA represents the upper end of the GVC series, boasting a robust heating capacity of 65,000 BTU. Designed for larger spaces, it features multiple heat settings, allowing users to customize their heating experience based on specific needs. The unit’s sleek design not only provides aesthetic value but also incorporates a built-in blower option, enhancing air circulation and ensuring even heat distribution. Safety remains a priority with the GVC65NA, which includes an ODS as well as a built-in thermostat for precise temperature control.

All models in the GVC series come equipped with simple control mechanisms, ensuring ease of use. They also utilize glowing ceramic elements for efficient and effective heating. Furthermore, the stylish exterior and compact design of these heaters make them an attractive addition to any room.

In summary, the Desa GVC35NA, GVC65NA, and GVC50NA heaters provide a comprehensive range of heating solutions, combining efficiency, safety, and ease of use. Their vent-free operation, built-in safety features, and aesthetic designs make them ideal choices for a variety of heating needs. Whether for small, medium, or large spaces, there is a GVC model to meet specific requirements, ensuring comfort and warmth for users.