CLEANING AND MAINTENANCE

WARNING

Turn off heater and let cool before cleaning or servicing.

WARNING

Keep heater clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

CAUTION

You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater and venting system inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

COMBUSTION CHAMBER AND BURNER

Clean the combustion chamber and burner if you have run the heater with a high yellow flame. Incomplete combustion from lack of air causes the yellow flame. This will deposit soot inside the combustion chamber and on the burner. To clean combustion chamber and burner, you must remove the burner from heater. See

Service Procedures, page 28, to remove burner. After removing burner, blow inside of combustion chamber clean with compressed air. Clean burner with a steel-wire brush. Blow soot from burner with compressed air.

PILOT

Use a vacuum cleaner, compressed air, or small, soft-bristled brush to clean.

BURNER ORIFICE

Use a vacuum cleaner, compressed air, or small, soft-bristled brush to clean. You can also use a tooth pick to clean orifice. Do not enlarge or damage orifice hole.

PILOT AND BURNER FLAME

Check the pilot and burner flame monthly. Make sure pilot and burner flame is burning correctly. See Inspecting Pilot and Burner Flame, page 21.

VENTING SYSTEM

Check the venting system at least once a year. Make sure joints are secure and vent pipe is in good condition. Do not obstruct combustion and ventilation air entering the rear of heater.

BLOWER MOTOR (For Models with Blower)

The motor on a new blower is properly lubricated at the factory. The first heating season, the motor will need no additional care. At the beginning of each season afterwards, place a few drops of SAE 20 motor oil in the lubrication holes of motor. Locate the lubrication holes at front and rear of motor on motor casing.

23

100749

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Carbon monoxide poisoning may lead to death Safety InformationSafety Information Product Identification Check GAS Type Local Codes Unpacking Product FeaturesInstallation Items Heater Clearances Locating HeaterVenting Heater Do not vent heater in any of the following ways see Figure Venting HeaterVenting Heater Proper Size Vent Connecting Heater to Utility Gas Line Connecting to GAS SupplyGas Connection Checking GAS Connections Pressure Testing Gas Supply Piping SystemFresh AIR for Combustion and Ventilation Draft Hood Spillage Test Determining FRESH-AIR Flow for Heater LocationVentilation Air from Outdoors Example 2 Locating Heater in Confined Closed Area Lighting Instructions For Your Safety Read Before LightingOperating Heater Viewing Pilot Shutting Off Heater Manual Lighting Procedure Blower Operation To Turn OFF GAS to ApplianceBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Correct Burner Flame Pattern Cleaning and Maintenance Observed Possible Problem Cause Remedy Trouble ShootingTROUBLE- Shooting Cleaning and MainteLighting Instructions Top Ing statement atRemoving Control Valve and Burner Tube Service ProceduresRemoving Burner Changing Burner Orifice Blower WiringDiagram Model Technical ServiceService Hints Accessories 35,000 BTU/Hr 50,000 BTU/HrParts Not Under Warranty Ordering Replacement Parts CentralsParts Under Warranty Cabinet Assembly Illustrated Parts ListBurner Assembly Parts List Limited Warranty Vanguard Vented Natural GAS Heaters Warranty Information