Desa CSBPT CSPBNT, CSPIPT, CSPBPT CSPINT, CSBNT installation manual Product Identification

Page 3

SAFETY INFORMATION PRODUCT IDENTIFICATION

3

SAFETY INFORMATION

Continued

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This heater shall not be installed in a bedroom or bathroom.

5.Do not place stove directly on carpeting, vinyl tile, or any combustible material other than wood. The stove must set on a metal or wood panel extending the full width and depth of the appliance.

6.Do not use this stove as a wood burning fireplace. Use only model 111485-02/111485-01 vent-free gas log heater.

7.Do not add extra logs or ornaments such as pine cones, vermicu- lite, or rock wool. Using these added items can cause sooting.

8.This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and heater burning manufacturing residues.

9.To prevent the creation of soot, follow the instructions in Clean- ing and Maintenance, page 13.

10.Before using furniture polish, wax, carpet cleaners, or similar products, turn heater off. If heated, the vapors from these prod- ucts may create a white powder residue within burner box or on adjacent walls or furniture.

11.This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, page 4. If heater keeps shutting off, see Troubleshooting, page 14.

12.Do not run heater

where flammable liquids or vapors are used or stored

when under dusty conditions

13.Do not use this stove to cook food or burn paper or other objects.

14.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

15.Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime-sized or larger).

16.Turn heater off and let cool before servicing. Only a qualified service person should service and repair heater.

17.Operating heater above elevations of 4,500 feet could cause pilot outage.

18.For propane/LP units, do not use propane/LP tank of less than 100 lb. capacity.

19.Provide adequate clearances around air openings.

20.Screen must be completely closed before using heater. Never run heater with screen open.

PRODUCT IDENTIFICATION

Stove Body

Screen

One Piece Log

Set Inside Stove

Cavity

Piezo Ignitor

Control Knob

Stove Door (Shown in the open position)

Figure 1 - Typical Stove Cabinet Model with Comfort Glow Gas Log Heater

For morevisit www..com

111487-01C

Image 3
Contents What to do if YOU Smell GAS CSBNT, Csbpt CSPBNT, Cspbpt CSPINT, CspiptSafety Information Table of ContentsTypical Stove Cabinet Model with Comfort Glow Gas Log Heater Product IdentificationProduct Features Local CodesAIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building Installation UnpackingVentilation Air From Outdoors Minimum Wall and Ceiling Clearances see Figure Clearances to Combustibles Vent-Free Operation OnlyInstallation Items Needed Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Installing ROD and ScreenLighting Instructions Installing LOG SETFor Your Safety Read Before Lighting Operating HeaterTo Turn OFF GAS To Appliance Manual Lighting ProcedureInspecting Burners Thermostat Control OperationLogs Cleaning MaintenanceMain Burner Burner Injector Holder and Pilot AIR Inlet HoleObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. SeeWarning statement at Accessories SpecificationsReplacement Parts Service Hints Technical ServiceModels Illustrated Parts BreakdownDescription QTY Parts ListStove Body Models CSB SERIES, Cspb SERIES, and Cspi Series CSB Series Cspb Series Cspi Series Parts Centrals Owners Registration Form Postage Required 111487-01C Warranty Information