SPECIFICATIONS

 

CSBPT, CSPBPT, CSPIPT

 

(Includes 111485-01 Burner Chassis)

Btu (Variable)

16,000/30,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Manifold

8" W.C.

Inlet Gas Pressure (in. of water)

Maximum

14"

Minimum*

11"

Shipping Weight

265 lbs.

* For input adjustment

 

CSBNT, CSPBNT, CSPINT

 

(Includes 111485-02 Burner Chassis)

Btu (Variable)

16,000/30,000

Type Gas

Natural Gas Only

Ignition

Piezo

Pressure Manifold

3.5" W.C.

Inlet Gas Pressure (in. of water)

Maximum

10.5"

Minimum*

5"

Shipping Weight

265 lbs.

* For input adjustment

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ technical service web site at www.desatech.com.

ACCESSORIES

Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA Heating Products at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products’ Techni- cal Service Department at 1-866-672-6040.

EQUIPMENT SHUTOFF VALVE - GA5010

For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.

When calling DESA Heating Products, have ready

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (see page 22) orcallDESAHeatingProductsat1-866-672-6040forreferralinformation.

When calling DESA Heating Products, have ready

model number of your heater

the replacement part number

CLEANING KIT - CCK (Not Shown)

For all models. Your vent-free gas appliance requires regular cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.

INFORMATION VIDEO - 108917-01

For all models. A care and maintenance video is available by calling 1-866-672-6040. You may also email your request to

productsupport@desaint.com.

For morevisit www..com

111487-01C

Image 17
Contents What to do if YOU Smell GAS CSBNT, Csbpt CSPBNT, Cspbpt CSPINT, CspiptSafety Information Table of ContentsTypical Stove Cabinet Model with Comfort Glow Gas Log Heater Product IdentificationAIR for Combustion and Ventilation Product FeaturesLocal Codes Ventilation Air From Inside Building Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors InstallationUnpacking Minimum Wall and Ceiling Clearances see Figure Clearances to Combustibles Vent-Free Operation OnlyInstallation Items Needed Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Installing ROD and ScreenFor Your Safety Read Before Lighting Installing LOG SETOperating Heater Lighting InstructionsInspecting Burners Manual Lighting ProcedureThermostat Control Operation To Turn OFF GAS To ApplianceMain Burner Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole LogsObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. SeeWarning statement at Replacement Parts Service Hints SpecificationsTechnical Service AccessoriesModels Illustrated Parts BreakdownDescription QTY Parts ListStove Body Models CSB SERIES, Cspb SERIES, and Cspi Series CSB Series Cspb Series Cspi Series Parts Centrals Owners Registration Form Postage Required 111487-01C Warranty Information