Table B-3Power requirements

Specification

110-volt models

220-volt models

 

 

 

Power requirements

100 to 127 volts (± 10%)

220 to 240 volts (± 10%)

 

50/60 Hz (± 2 Hz)

50/60 Hz (± 2 Hz)

 

 

 

Rated current

8.5 Amps

4.5 Amps

 

 

 

Table B-4Power consumption (average, in watts)1246

Product model

Printing

Ready

Sleep

Off

 

 

 

 

 

HP Color LaserJet CP4525 model

740 W

72 W

19 W

0.3 W

HP Color LaserJet CP4025 model

 

 

 

 

1Values subject to change. See www.hp.com/go/cljcp4025_regulatory or www.hp.com/go/cljcp4525_regulatory for current information.

2Power numbers are the highest values measured using all standard voltages.

3Default time from Ready mode to Sleep = 30 minutes.

4Heat dissipation in Ready mode = 204.8 BTU/hour.

6HP Color LaserJet CP4525 speed is 30 ppm Letter size.

Acoustic specifications

Table B-5HP Color LaserJet Enterprise CP4020-CP4520 Series13

Sound power level

Declared per ISO 9296

 

 

Printing

LWAd= 6.9 Bels (A) [69 dB(A)]

 

 

Ready

LWAd= 5.0 Bels (A) [50 dB(A)]

 

 

Sound pressure level - bystander position

Declared per ISO 9296

 

 

Printing

LpAm=54 dB (A)

 

 

Ready

LpAm=35 dB (A)

1Values are based on preliminary data. See www.hp.com/go/cljcp4025_regulatory or www.hp.com/go/cljcp4525_regulatory for current information.

3Configuration tested: HP Color LaserJet CP4525 printer printing on A4-size paper in simplex mode

Environmental specifications

Environmental condition

Recommended

Allowed

 

 

 

Temperature (product and print

17° to 27°C (62.6° to 80.6°F)

10° to 30°C (50° to 86°F)

cartridge)

 

 

 

 

 

Relative humidity

30% to 70% relative humidity (RH)

10% to 80% RH

 

 

 

Altitude

N/A

0 m (0 ft) to 3000 m (9842 ft)

 

 

 