The DC controller determines if a motor has failed and notifies the formatter when it encounters the following conditions:

Startup failure: the motor does not reach a specified speed within a specified time from when the motor starts.

Rotational failure: the rotational speed of the motor is not in the specified range for a specified time after the motor reaches a specified speed.

Lock detection (for the residual toner feed motor): the value of the motor drive signal voltage is not in the specified range for a specified time.

Fans

The product has four fans for preventing the temperature from rising in the product.

Table 1-6 Fans

Abbreviation

Name

Cooling area

Type

Speed

 

 

 

 

 

FM1

Power supply fan

Around the power

Intake

Full/half

 

 

supply unit

 

 

 

 

 

 

 

FM2

Cartridge fan

Around the cartridges

Intake

Full/half

 

 

 

 

 

FM3

Delivery fan

Around the delivery unit

Intake

Full/half

 

 

 

 

 

FM4

Exhaust fan 1

Around the cartridge

Exhaust

Full/half

 

 

 

 

 

The DC controller determines if there is a fan failure and notifies the formatter if the fan locks for a specified time from when the fan starts.

ENWW

Engine-control system 9

Page 41
Image 41
HP CP4525DN Laser CC494A#ABA manual Fans, Abbreviation Name Cooling area Type Speed