Manual sensor test (special-mode test)

Use this diagnostic test to manually test the product sensors and switches. Each sensor is represented by a letter and number on the control panel display.

1.Press the Home button .

2.Press the down arrow to highlight the DIAGNOSTICS menu, and then press the OK button.

3.Press the down arrow to highlight the MANUAL SENSOR TEST option, and then press the OK button.

To exit this diagnostic, press the Stop button , and then select EXIT DIAGNOSTICS.

Menus cannot be opened during this test, so the OK button serves the same function as the Stop button

.

Table 3-3Manual sensor diagnostic tests

Sensor or switch name

Sensor or switch number

 

 

A TOP (top of page) sensor

SR20

 

 

B loop 1 sensor

SR14

 

 

C loop 2 sensor

SR15

 

 

D fuser delivery sensor

SR5

 

 

E duplex re-pickup sensor

SR22

 

 

F output bin full sensor

SR6

 

 

G

Not used

 

 

H

Not used

 

 

I developer alienation

SR11

 

 

J fuser pressure-release sensor

SR7

 

 

K primary transfer-roller-disengagement sensor

SR9

 

 

L media sensor

SR21

 

 

M front door open

SW5

 

 

N right door open

SW6

 

 

When performing these tests, watch for the corresponding bit to toggle from 1 to 0 or 0 to 1. It can take a few seconds for bits to toggle.

Table 3-4

Default state of bits

 

 

 

 

 

 

 

 

 

 

Label

A

B

C

D

E

F

G

H

I

J

K

L

M

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit

1

1

1

1

0

0

0

0

0

1

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

246 Chapter 3 Solve problems