Table 3-14Control-panel messages (continued)

Description

Recommended action

 

 

 

 

 

59.63 ERROR

Yellow image drum motor rotation error

Perform the drum-motors component test in

 

 

the DIAGNOSTICS menu. If the message

 

 

persists, replace the yellow drum motor. See

 

 

Yellow, magenta, cyan, and black drum

 

 

motors on page 199.

 

 

 

59.90 ERROR

ITB motor startup error

Reconnect the connector J14 of the ITB

 

 

motor and the connector J140 on the DC

 

 

controller PCA. Perform the ITB motor drive

 

 

component test to verify that the ITB motor is

 

 

functioning properly. If the message persists,

 

 

replace the ITB motor. See ITB motor

 

 

on page 202.

 

 

 

59.A0 ERROR

ITB motor rotation error.

Use the component test to activate the ITB

 

 

motor. If the motor does not function, replace

 

 

the motor. See ITB motor on page 202.

 

 

 

 

59.BO CLEANING MOTOR ERROR

The residual-toner feed motor has failed.

1.

Check the toner collection unit. If the unit

REPLACE TONER COLLECTION UNIT

 

 

is full, replace it.

 

 

NOTE: Toner can clog the feed motor

 

 

 

 

 

 

if the toner collection unit is full.

 

 

2.

Reconnect the residual-toner feed

 

 

 

motor connector J63 and connector

 

 

 

J155 on the DC controller PCA.

 

 

3.

Replace the residual-toner feed motor.

 

 

 

See Residual-toner-feed motor

 

 

 

on page 133.

 

 

 

 

59.C0 ERROR

Developer alienation motor rotation error

1.

Reconnect intermediate connector J87

 

 

 

of the developing disengagement

 

 

 

sensor, connector J112 on the DC

 

 

 

controller PCA, connector J38 of the

 

 

 

developing disengagement motor, and

 

 

 

the connector J261 on the high-voltage

 

 

 

power supply D PCA.

 

 

2.

Run the sensor test in the sensor

 

 

 

monitor mode to verify that the

 

 

 

developing disengagement sensor is

 

 

 

functioning properly. If it is not, replace

 

 

 

the main-drive assembly. See Main-

 

 

 

drive assembly on page 203.

 

 

3.

Run the developing unit disengagement

 

 

 

drive test to verify that the

 

 

 

disengagement mechanism is

 

 

 

functioning properly. If it is not, replace

the developing disengagement motor. See Developing-disengagement motor on page 168.

ENWW

Tools for troubleshooting 353

Page 385
Image 385