Desa VN2000BTA, VN2800BTA, VN2000BA installation manual TROUBLE- Shooting

Page 26

26

TROUBLE- SHOOTING

Continued

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

Burner does not light

1.

Burner orifice is

1.

Clean burner (see

after ODS/pilot is lit

 

clogged

 

Cleaning and Mainte-

 

 

 

 

nance, page 24) or

 

 

 

 

replace burner orifice

 

2.

Burner orifice diameter

2.

Replace burner orifice

 

 

is too small

 

 

 

3.

Inlet gas pressure is

3.

Contact local natural gas

 

 

too low

 

company

 

 

 

 

 

Delayed ignition of

1.

Manifold pressure is

1.

Contact local natural gas

burner

 

too low

 

company

 

2.

Burner orifice is

2.

Clean burner (see

 

 

clogged

 

Cleaning and Mainte-

 

 

 

 

nance, page 24) or

 

 

 

 

replace burner orifice

 

 

 

 

 

Burner backfiring

1.

Burner orifice is

1.

Clean burner (see

during combustion

 

clogged or damaged

 

Cleaning and Mainte-

 

 

 

 

nance, page 24) or

 

 

 

 

replace burner orifice

 

2.

Burner damaged

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

Yellow flame during

1. Not enough air

1.

Check burner for dirt

burner combustion

 

 

 

and debris. If found,

 

 

 

 

clean burner (see

 

 

 

 

Cleaning and Mainte-

 

 

 

 

nance, page 24)

 

2.

Gas regulator defective

2.

Replace gas regulator

 

 

 

 

Slight smoke or odor

1. Residues from manu-

1.

Problem will stop after a

during initial opera-

 

facturing processes

 

few hours of operation

tion

 

 

 

 

 

 

 

 

Heater produces a

1. Turning control knob

1.

Turn control knob to LO

whistling noise when

 

to HI position when

 

position and let warm up

burner is lit

 

burner is cold

 

for a minute

 

2.

Air in gas line

2.

Operate burner until air

 

 

 

 

is removed from line.

 

 

 

 

Have gas line checked

 

 

 

 

by local natural gas

 

 

 

 

company

 

3.

Air passageways on

3.

Observe minimum

 

 

heater blocked

 

installation clearances

 

 

 

 

(see Figure 4, page 10)

 

4.

Dirty or partially

4.

Clean burner (see

 

 

clogged burner orifice

 

Cleaning and Mainte-

 

 

 

 

nance, page 24) or

 

 

 

 

replace burner orifice

099570

Image 26
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information001 Unpacking Product IdentificationLocal Codes ProductVentilation Fresh AIR ForCombustion Producing Adequate VentilationDetermining if You Have a Confined or Unconfined Space Fresh AIRDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Fresh AIR for Combustion and VentilationVentilation AIR Ventilation AIR Ventilation Air From OutdoorsCheck GAS Type Installing To WallInstallation Items Locating HeaterLocating Thermostat Sensing Bulb Thermostat Sensing BulbModels VN2000BTA and VN2800BTA Only Attaching Thermostat Sensing BulbRemoving Front Panel Of Heater Installing Heater to WallMounting Bracket Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply Use pipe joint sealant that is resistant to natural gasConnections Pressure Testing GAS Supply Piping SystemChecking GAS Servicing. Correct all leaks at oncePressure Testing Heater GAS Connections CheckingFor Your Safety Read Before Lighting Operating HeaterOperating HeaterShutting Off Heater Shutting Off Burner Only pilot stays litModel VN2000BA Model VN2000BA Inspecting Burner Pilot Flame PatternBurner Flame Pattern InspectingBurner Tipping, follow instructions at bottom of thisCabinet Trouble ShootingODS/PILOT and Burner Air PassagewaysCleaning and Mainte TroubleTROUBLE- Shooting Do not try to light any appliance If you smell gasShut off gas supply Ing statement atVN2000BA Technical ServiceService Hints Parts Not Under Warranty Service Publications Replacement PartsParts Under Warranty Models VN2000BA & VN2000BTA GA4000B Model VN2800BTA GA4010B AccessoriesFAN Kits GA2100A and GA3100 Valve GA5010Illustrated Parts List Manual Control Model VN2000BA Parts list onShown, See Page 31 for Manual Control Valve Parts List VN2000BTA VN2800BTA Description QTY099570 099570 Warranty Information Keep this Warranty

VN2000BA, VN2000BTA, VN2800BTA specifications

Desa VN2800BTA, VN2000BTA, and VN2000BA are three models of innovative heating solutions that embody advanced technology and comfort for residential and commercial use. These models are designed to provide efficient heating in various settings, ensuring warmth during the colder months while prioritizing user convenience and energy savings.

The VN2800BTA model stands out for its impressive heating capacity, making it suitable for larger spaces. It features a powerful output, capable of quickly warming a room while maintaining a consistent temperature. This model utilizes a user-friendly thermostat that allows for precise temperature control, ensuring optimal comfort without unnecessary energy consumption.

In contrast, the VN2000BTA and VN2000BA are designed for medium-sized areas, offering flexibility in different room configurations. Both models incorporate similar technological features, such as electronic ignition systems that enhance reliability and convenience. Owners can benefit from quick heat-up times, ensuring their environment remains cozy and inviting.

One of the defining characteristics of all three models is their commitment to safety. Each unit is equipped with built-in safety features, including oxygen depletion sensors and automatic shut-off mechanisms. These technologies provide peace of mind for users, allowing them to enjoy their heating systems without concern for safety hazards.

Additionally, all three models are designed with energy efficiency in mind. They utilize advanced combustion technologies that optimize fuel usage, resulting in reduced operational costs over time. This not only benefits the user financially but also contributes to lower environmental impact, aligning with modern sustainability goals.

In terms of aesthetics, the VN2800BTA, VN2000BTA, and VN2000BA models offer a sleek design that can blend seamlessly into any décor. The options for venting make installation versatile and adaptable to different home layouts, allowing for a customized heating solution.

Furthermore, the user experience is enhanced through easy-to-read displays and intuitive controls. This modern interface gives users a seamless interaction with their heating system, making adjustments a simple task.

Overall, Desa VN2800BTA, VN2000BTA, and VN2000BA models combine efficiency, safety, and style, making them an excellent choice for anyone looking to enhance their indoor comfort during chilly weather. With their robust features and user-focused design, these models set a high standard in the heating appliance market.