Desa VN2800BTD Lighting Instructions, To Turn OFF GAS To Appliance, Thermostat Control Operation

Page 12

®

BLUE FLAME NATURAL GAS HEATER

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, column 3, page 11.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information in column 3, page 11. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) sec- onds (see Figure 16).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.

Ignitor Button

 

Control Knob

 

PILOT

LO

 

OFF

 

 

HI

 

IGNITOR

 

 

Figure 16 - Control Knob In The OFF Position

Note: If pilot does not stay lit, refer to Troubleshooting, pages 14 through

16.Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

• If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps

3through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise

to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 17 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

THERMOSTAT

CONTROL

OPERATION

The thermostatic control used on these models differs from standard thermo- stats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room tem- perature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO. Selecting the HI setting will cause the burner to remain fully on without modu- lating down in most cases.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation loca- tion, room size, open air temperatures, etc.). Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 7, page 8).

2.Follow steps 1 through 5 under Light- ing Instructions.

3.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, column 2.

5.Replace front panel.

12

104402

Image 12
Contents Blue Flame VENT-FREE Natural GAS Heater What to do if YOU Smell GASSafety Information Blue Flame Natural GAS HeaterProduct Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation ItemsCheck GAS Type Locating HeaterInstalling Heater to Wall Installing Bottom Mounting Screws Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket Connecting to GAS Supply Typical Inlet Pipe DiametersFor Your Safety Read Before Lighting Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Operating HeaterManual Lighting Procedure Lighting InstructionsTo Turn OFF GAS To Appliance Thermostat Control OperationCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Gas leak. See Warning statement atSpecifications Replacement PartsAccessories Technical ServiceODS/Pilot Assembly Illustrated Parts BreakdownVN2000BTD VN2800BTD Parts List Under Replacement Parts on page 17 of this manualWarranty Information

VN2000BTD, VN2800BTD specifications

The Desa VN2800BTD and VN2000BTD are two advanced space heaters that represent the pinnacle of technology and design in the heating industry. Both models are engineered for efficiency, ensuring warmth and comfort in various settings, from homes to workshops.

One of the primary features of the VN2800BTD and VN2000BTD is their versatility in application. They are ideal for supplemental heating, capable of warming up rooms quickly and effectively with an easy-to-use design. The VN2800BTD boasts an output of 28,000 BTUs, while the VN2000BTD offers a slightly lower but still robust output of 20,000 BTUs. This makes them suitable for a diverse range of spaces and heating needs.

A key characteristic of these models is their advanced technology, which includes a forced air heating mechanism. This system allows heated air to circulate rapidly throughout the room, providing even warmth without the cold spots often found in traditional heaters. Both units are fueled by propane, making them highly efficient and eco-friendly compared to electric options.

Safety is another significant aspect of the Desa VN2800BTD and VN2000BTD. These models are equipped with automatic shut-off features that activate in case of a malfunction or if the heater tips over. Additionally, they have built-in oxygen depletion sensors that monitor air quality, ensuring safe operation in enclosed spaces. This focus on user safety reflects Desa's commitment to providing reliable heating solutions.

The design of the VN2800BTD and VN2000BTD is pragmatic and attractive, allowing them to blend seamlessly into any environment. They come with a durable construction that ensures longevity, even under demanding conditions. Portability is another benefit; both models often feature handles or wheels that make it easy to transport them from one area to another, enhancing their utility.

Easy ignition systems are another highlight, with many units incorporating a piezo ignition feature that allows for quick and reliable starts. This user-friendly approach minimizes the hassle often associated with traditional heating methods.

In summary, the Desa VN2800BTD and VN2000BTD heaters are exemplary products that combine powerful heating capabilities with safety and user convenience. Their advanced technology and thoughtful features make them an outstanding choice for anyone looking to enhance their comfort through effective space heating solutions.