Desa VN2800BTD, VN2000BTD installation manual Blue Flame Natural GAS Heater, Safety Information

Page 2

®

BLUE FLAME NATURAL GAS HEATER

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural Gas: Natural gas is odorless. An odor-making agent is added to natural gas. The odor helps you detect a natural gas leak. However, the odor added to natural gas can fade. Natural gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not use any accessory not approved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will re- main hot for a time after shut- down. Allow surface to cool be- fore touching.

Carefully supervise young chil- dren when they are in the same room with heater.

Make sure grill guard is in place before running heater.

Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

3.This heater shall not be installed in a bedroom or bathroom.

4.This heater needs fresh, outside air ven- tilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6.

5.Keep all air openings in front and bot- tom of heater clear and free of debris. This will insure enough air for proper combustion.

6.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.

7.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

8.Do not use heater if any part has been under water. Immediately call a quali- fied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

9.Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.

10.Operating heater above elevations of 4,500 feet could cause pilot outage.

2

104402

Image 2
Contents Blue Flame VENT-FREE Natural GAS Heater What to do if YOU Smell GASSafety Information Blue Flame Natural GAS HeaterLocal Codes Product FeaturesProduct Identification UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items Locating HeaterInstalling Heater to Wall Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsAttaching Mounting Bracket To Wall Connecting to GAS Supply Typical Inlet Pipe DiametersPressure Testing Heater Gas Connections For Your Safety Read Before LightingPressure Testing Gas Supply Piping System Operating HeaterTo Turn OFF GAS To Appliance Manual Lighting ProcedureLighting Instructions Thermostat Control OperationCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Gas leak. See Warning statement atAccessories SpecificationsReplacement Parts Technical ServiceVN2000BTD VN2800BTD ODS/Pilot AssemblyIllustrated Parts Breakdown Parts List Under Replacement Parts on page 17 of this manualWarranty Information

VN2000BTD, VN2800BTD specifications

The Desa VN2800BTD and VN2000BTD are two advanced space heaters that represent the pinnacle of technology and design in the heating industry. Both models are engineered for efficiency, ensuring warmth and comfort in various settings, from homes to workshops.

One of the primary features of the VN2800BTD and VN2000BTD is their versatility in application. They are ideal for supplemental heating, capable of warming up rooms quickly and effectively with an easy-to-use design. The VN2800BTD boasts an output of 28,000 BTUs, while the VN2000BTD offers a slightly lower but still robust output of 20,000 BTUs. This makes them suitable for a diverse range of spaces and heating needs.

A key characteristic of these models is their advanced technology, which includes a forced air heating mechanism. This system allows heated air to circulate rapidly throughout the room, providing even warmth without the cold spots often found in traditional heaters. Both units are fueled by propane, making them highly efficient and eco-friendly compared to electric options.

Safety is another significant aspect of the Desa VN2800BTD and VN2000BTD. These models are equipped with automatic shut-off features that activate in case of a malfunction or if the heater tips over. Additionally, they have built-in oxygen depletion sensors that monitor air quality, ensuring safe operation in enclosed spaces. This focus on user safety reflects Desa's commitment to providing reliable heating solutions.

The design of the VN2800BTD and VN2000BTD is pragmatic and attractive, allowing them to blend seamlessly into any environment. They come with a durable construction that ensures longevity, even under demanding conditions. Portability is another benefit; both models often feature handles or wheels that make it easy to transport them from one area to another, enhancing their utility.

Easy ignition systems are another highlight, with many units incorporating a piezo ignition feature that allows for quick and reliable starts. This user-friendly approach minimizes the hassle often associated with traditional heating methods.

In summary, the Desa VN2800BTD and VN2000BTD heaters are exemplary products that combine powerful heating capabilities with safety and user convenience. Their advanced technology and thoughtful features make them an outstanding choice for anyone looking to enhance their comfort through effective space heating solutions.