WARNING: Turn off heater and let cool before cleaning.

CAUTION:Youmustkeepcon- trol areas, burner and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

1.Remove the two screws that hold the front log bracket onto the assembly (see Figure 23). The log is attached to this bracket. Gently lift up on the log and bracket. Set aside.

2.Inspect burner and primary air inlet holes on injector holder for dust and dirt (see Figure 24).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

Burner Injector Holder

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every

Front

Log

Figure 23 - Removing Front Log to Clean

Front Burner

three months during operation and have heater inspected yearly by a qualified service person. We also recommend that you keep the burner tube clean and free of dust and dirt. We recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. You can

Injector Holder

Burner Tube

use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the direc- tions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

Before cleaning, shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. You will need to remove the front log to access the front burner.

Injector

Primary Air

Inlet Opening

Figure 24 - Injector Holder on Front

Burner Tube

111826-04C

www.desatech.com

19

Image 19
Contents What to do if YOU Smell GAS Table of Contents Safety information Product Identification Product IdentificationAir For Combustion Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Determining fresh-air flow for heater locationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationMinimum Fireplace Clearance to Combustible Materials Installation and clearances for vent-free operationLOG Sizing Requirements Material Requirements for Distance a Safe Installation InstallationFloor Clearances Installing Heater AssemblyDetermining Minimum Mantel Clearance When using a Hood Mantel ClearancesInstallation Items Needed Connecting to gas supplyNatural Gas Checking gas connectionsPropane/LP Gas Test Pressures Equal To or Less Than Psig 3.5 kPa For your safety Read before lightingPressure Testing Heater Gas Connections Operating HeaterBattery Remote ControlFunctions Battery Replacement Shut-off ProcedureSetting The Display C/24h and F /12h Setting The TimeTo turn gas off To appliance ProcedureManual Lighting Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Burner Injector Holder Cleaning MaintenanceObserved Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte Gas leak. See Warning Bad module Replace moduleIdentifying error signals from reciever Wiring DiagramParts Under Warranty Service HintsTechnical Service Replacement PartsAccessories SpecificationsCleaning KIT GCK Models VF-18N-PJD and vf-18p-pjd Illustrated Parts BreakdownParts List Models VF-24N-PJD and vf-24p-pjd KEY Part Number VF-24N-PJD VF-24P-PJD Description QTY Models VF-30N-PJD and vf-30p-pjd KEY Part Number VF-30N-PJD VF-30P-PJD Description QTY Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters