Desa VF-30P-PJD, VF-30N-PJD, VF-24N-PJD, VF-24P-PJD, VF-18N-PJD, VF-18P-PJD Natural Gas

Page 13

INSTALLATION

Continued

Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 12).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special re- quirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

To Gas

CSA Design-Certified

Equipment Shutoff Valve

Control

With 1/8" NPT Tap*

 

 

 

Natural Gas

 

 

From Gas Meter

Approved

 

(5" W.C.** to 10.5"

 

W.C. Pressure)

Flexible Gas

 

 

Propane/LP Gas

Hose (if allowed

From External

by local codes)

 

 

Regulator

 

 

 

 

(11" W.C.** to

3" Minimum

14" W.C.

Pressure)

 

 

Cap Pipe Tee

Nipple Joint

Sediment Trap

Figure 12 - Gas Connection

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See

Accessories, page 25.

** Minimum inlet pressure for purpose of input adjustment.

We recommend that you install a sediment trap in supply line as shown in Figure 12. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

CAUTION: Avoid damage to gas control. Hold gas control with wrench when connecting it to gas piping and/or fittings.

checking gas connections

WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detec- tion fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION: Make sure exter- nal regulator has been installed between propane/LP supply and heater. See guidelines un- der Connecting to Gas Supply, page 12.

pressure testing gas supply piping system

Test Pressures In Excess Of 1/2 PSIG

(3.5 kPa)

1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2. Cap off open end of gas pipe where equipment shutoff valve was connected.

111826-04C

www.desatech.com

13

Image 13
Contents What to do if YOU Smell GAS Table of Contents Safety information Product Identification Product IdentificationLocal Codes Product FeaturesUnpacking Air For Combustion VentilationConfined and Unconfined Space Determining fresh-air flow for heater locationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationMinimum Fireplace Clearance to Combustible Materials Installation and clearances for vent-free operationLOG Sizing Requirements Material Requirements for Distance a Safe Installation InstallationDetermining Minimum Mantel Clearance When using a Hood Installing Heater AssemblyMantel Clearances Floor ClearancesInstallation Items Needed Connecting to gas supplyNatural Gas Checking gas connectionsPropane/LP Gas Pressure Testing Heater Gas Connections For your safety Read before lightingOperating Heater Test Pressures Equal To or Less Than Psig 3.5 kPaBattery Remote ControlFunctions Setting The Display C/24h and F /12h Shut-off ProcedureSetting The Time Battery ReplacementTo turn gas off To appliance ProcedureManual Lighting Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Burner Injector Holder Cleaning MaintenanceObserved Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte Gas leak. See Warning Bad module Replace moduleIdentifying error signals from reciever Wiring DiagramTechnical Service Service HintsReplacement Parts Parts Under WarrantyAccessories SpecificationsCleaning KIT GCK Models VF-18N-PJD and vf-18p-pjd Illustrated Parts BreakdownParts List Models VF-24N-PJD and vf-24p-pjd KEY Part Number VF-24N-PJD VF-24P-PJD Description QTY Models VF-30N-PJD and vf-30p-pjd KEY Part Number VF-30N-PJD VF-30P-PJD Description QTY Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters