Desa CBT30NT, CBT30PT installation manual Safety Information

Page 3

SAFETY INFORMATION

WARNING:Thisproductcon- tainsand/orgenerateschemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with head- aches, dizziness or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influ- ence of alcohol and those at high altitudes.

Natural and Propane/LP Gas: Natural and Propane/ LP gases are odorless. An odor-making agent is added to these gases. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warn- ings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not use a blower insert, heat exchanger insert or other accessory not ap- proved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut- down. Allow surface to cool before touching.

Carefully supervise young chil- dren when they are in the same room with heater.

Make sure grill guard is in place before running heater.

Keep the appliance area clear and free from combustible ma- terials, gasoline and other flam- mable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This ap- pliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) in- side any structure. Locate propane/LP supply tank(s) outdoors.

3.This heater shall not be installed in a bedroom or bathroom.

4.If you smell gas

Shut off gas supply

Do not try to light any appliance

Do not touch any electrical switch; do not use any phone in your building

Immediately call your gas supplier from a neighborʼs phone. Follow the gas supplierʼs instructions

If you cannot reach your gas supplier, call the fire department

107882-01M

www.desatech.com

3

Image 3
Contents What to do if YOU Smell GAS Table of Contents Safety Information Ignition System Product FeaturesSafety Device Local CodesUnusually Tight Construction AIR for Combustion VentilationProviding Adequate Ventilation Following are excerpts from National FuelVentilation Air From Inside Building Determining FRESH-AIR Flow for Heater LocationVentilation AIR Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors AIR for Combustion Ventilation InstallationInstallation Items Check GAS TypeThermostat Sensing Bulb Locating HeaterMarking Screw Locations Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsAttaching To Wall Stud Method Attaching To Wall Anchor MethodMounting Base Feet to Heater Connecting to GAS SupplyMounting Base Feet to Floor Where required by local code Mounting Heater to Floor OptionalClogged heater valves Dealer. See Accessories,Be upstream from heater see Figure Appliance Apply pipe joint sealant lightly to male NPTChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa For Your Safety Read Before Lighting Operating HeaterLighting Instructions Thermostat Control Operation Manual Lighting ProcedureInspecting Heater To Turn OFF GAS To ApplianceBurner Pilot AIR Inlet Soft bristled brush to cleanBurner Flame Pattern ODS/PILOT and BurnerWhen Gas Pressure Is Too Low Cleaning MaintenanceService Hints Technical ServiceContact local propane/LP gas company TroubleshootingObserved Problem Possible Cause Remedy Control knob is not in pilot positionDelayed ignition of burners Manifold pressure is too low Goes out when control knob is Control knob not pressedProblem could be caused by AssemblyInitial operation Processes Hours of operation Noise when burner is litWhen heated, vapors from Turn heater off when using Slight smoke or odor duringGas leak. See Warning Specifications Service Publications Replacement PartsIllustrated Parts Breakdown Parts List 111435-01 Electronic Ignitor 097159-04 Piezo IgnitorFront Panel 107954-01 107955-01 Floor Mounting KIT GA4550 AccessoriesEquipment Shutoff Valve GA5010 FAN Kits GA3250TParts Central Keep this Warranty Warranty Information

CBT30NT, CBT30PT specifications

The Desa CBT30NT and CBT30PT are high-performance heating solutions designed to deliver efficient warmth for both residential and commercial applications. These units are known for their reliability, innovative features, and easy integration into various spaces. They are particularly suited for those seeking effective heating options without compromising on energy efficiency.

The CBT30NT, or the natural gas version, stands out with its ability to provide consistent warmth through a direct vent system. This allows for safe operation while minimizing the impact on indoor air quality. It effectively draws combustion air from outside, which is essential for spaces with limited ventilation. The CBT30PT, on the other hand, is a propane variant, providing flexibility for users who may not have access to natural gas lines. Both models are designed with user convenience in mind, featuring a simple control system that allows for easy adjustments and temperature settings.

One of the key characteristics of these heaters is their advanced thermostat control, which enables precise temperature management. This feature ensures energy usage is optimized, preventing unnecessary heating and reducing utility costs. The compact and sleek design of the CBT30NT and CBT30PT allows them to fit seamlessly into any room without being an eyesore.

The heaters are equipped with durable materials, providing resilience against the rigors of daily use. They feature safety mechanisms, including flame failure safety devices, ensuring peace of mind for users. Furthermore, both models incorporate a forced air design, which disperses heat efficiently throughout the space, eliminating cold spots and creating a more uniform climate.

In summary, the Desa CBT30NT and CBT30PT are ideal heating solutions that combine safety, efficiency, and aesthetic appeal. Their natural gas and propane options respectively cater to a diverse range of user needs, making them versatile choices for enhanced comfort. With their advanced technology and user-friendly features, these heaters are a worthy investment for anyone in need of reliable heating solutions. Emphasizing energy efficiency and user safety, they represent the next generation of residential and commercial heating systems.