Desa CBT30NT, CBT30PT Local Codes, Product Features, Safety Device, Ignition System

Page 4

SAFETY INFORMATION

Continued

5.This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, page 5.

6.Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion.

7.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.

8.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

9.Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

10.Turn off and let cool before servicing. Only a qualified service person should service and repair heater.

11.Operating heater above elevations of 4,500 feet (1,371 m) could cause pilot outage.

12.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. (45 kg) capacity.

13.Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

14.Provide adequate clearances around air openings.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

 

PRODUCT

IDENTIFICATION

Heater

Control Knob & Ignitor Button

Cabinet

(not seen from this view)

 

Grill

 

Guard

Front Panel

Glass Panel (Blue

Flame Models Only)

Figure 1 - Vent-Free Gas Heater

UNPACKING

1.Remove heater from carton.

2.Remove all protective packaging applied to heater for shipment.

3.Check heater for any shipping damage. If heater is damaged, promptly return to where you bought heater.

PRODUCT FEATURES

SAFETY DEVICE

This heater has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

IGNITION SYSTEM

This heater has either a piezo ignitor or electronic ignitor to light heater fuel supply.

THERMOSTATIC HEAT CONTROL

Thermostat models have a thermostat sensing bulb and a control valve. This results in the great- est heater comfort. This can also result in lower gas bills.

4

www.desatech.com

107882-01M

Image 4
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Features Safety DeviceLocal Codes Ignition SystemAIR for Combustion Ventilation Providing Adequate VentilationFollowing are excerpts from National Fuel Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location Ventilation AIRDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside BuildingAIR for Combustion Ventilation Installation Installation ItemsCheck GAS Type Ventilation Air From OutdoorsLocating Heater Thermostat Sensing BulbInstalling Heater to Wall Mounting BracketRemoving Front Panel Of Heater Marking Screw LocationsInstalling Bottom Mounting Screws Attaching To Wall Stud MethodAttaching To Wall Anchor Method Placing Heater On Mounting BracketConnecting to GAS Supply Mounting Base Feet to Floor Where required by local codeMounting Heater to Floor Optional Mounting Base Feet to HeaterDealer. See Accessories, Be upstream from heater see FigureAppliance Apply pipe joint sealant lightly to male NPT Clogged heater valvesTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Operating Heater For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure Inspecting HeaterTo Turn OFF GAS To Appliance Thermostat Control OperationSoft bristled brush to clean Burner Flame PatternODS/PILOT and Burner Burner Pilot AIR InletCleaning Maintenance Service HintsTechnical Service When Gas Pressure Is Too LowTroubleshooting Observed Problem Possible Cause RemedyControl knob is not in pilot position Contact local propane/LP gas companyGoes out when control knob is Control knob not pressed Problem could be caused byAssembly Delayed ignition of burners Manifold pressure is too lowNoise when burner is lit When heated, vapors from Turn heater off when usingSlight smoke or odor during Initial operation Processes Hours of operationGas leak. See Warning Specifications Replacement Parts Service PublicationsIllustrated Parts Breakdown 111435-01 Electronic Ignitor 097159-04 Piezo Ignitor Parts ListFront Panel 107954-01 107955-01 Accessories Equipment Shutoff Valve GA5010FAN Kits GA3250T Floor Mounting KIT GA4550Parts Central Warranty Information Keep this Warranty

CBT30NT, CBT30PT specifications

The Desa CBT30NT and CBT30PT are high-performance heating solutions designed to deliver efficient warmth for both residential and commercial applications. These units are known for their reliability, innovative features, and easy integration into various spaces. They are particularly suited for those seeking effective heating options without compromising on energy efficiency.

The CBT30NT, or the natural gas version, stands out with its ability to provide consistent warmth through a direct vent system. This allows for safe operation while minimizing the impact on indoor air quality. It effectively draws combustion air from outside, which is essential for spaces with limited ventilation. The CBT30PT, on the other hand, is a propane variant, providing flexibility for users who may not have access to natural gas lines. Both models are designed with user convenience in mind, featuring a simple control system that allows for easy adjustments and temperature settings.

One of the key characteristics of these heaters is their advanced thermostat control, which enables precise temperature management. This feature ensures energy usage is optimized, preventing unnecessary heating and reducing utility costs. The compact and sleek design of the CBT30NT and CBT30PT allows them to fit seamlessly into any room without being an eyesore.

The heaters are equipped with durable materials, providing resilience against the rigors of daily use. They feature safety mechanisms, including flame failure safety devices, ensuring peace of mind for users. Furthermore, both models incorporate a forced air design, which disperses heat efficiently throughout the space, eliminating cold spots and creating a more uniform climate.

In summary, the Desa CBT30NT and CBT30PT are ideal heating solutions that combine safety, efficiency, and aesthetic appeal. Their natural gas and propane options respectively cater to a diverse range of user needs, making them versatile choices for enhanced comfort. With their advanced technology and user-friendly features, these heaters are a worthy investment for anyone in need of reliable heating solutions. Emphasizing energy efficiency and user safety, they represent the next generation of residential and commercial heating systems.