Desa 6000 BTU/HR Checking GAS Connections, Operating Heater, For Your Safety Read Before Lighting

Page 9

OWNER’S MANUAL

CHECKING GAS CONNECTIONS

WARNING: Test all gas pip- ing and connections for leaks after installation or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION: Make sure exter- nal regulator has been installed between propane/LP supply and heater. See guidelines under Con- necting to Gas Supply, page 8.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2

PSIG

1. Disconnect heater and its individual

3.Check all joints from propane/LP sup- ply tank to manual shutoff valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

PRESSURE TESTING

HEATER GAS

CONNECTIONS

1.Open manual shutoff valve (see Figure 14).

2.Open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from manual shutoff valve to control valve (see Figure 15). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 9 and 10). Check the rest of the internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 10).

8.Replace front panel.

OPERATING

HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A. This appliance has a pilot which

must be lighted by hand. When

lighting the pilot, follow these in-

structions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas.

Be sure to smell next to the floor

because some gas is heavier than air

and will settle on the floor.

WHAT TO DO IF YOU SMELL

GAS

Do not try to light any appliance.

Do not touch any electric switch;

 

do not use any phone in your

 

building.

• Immediately call your gas supplier

manual shutoff valve from gas supply

piping system. Pressures in excess of

Manual

Open

from a neighbor’s phone. Follow

 

1/2 Psig will damage heater regulator.

2.

Cap off open end of gas pipe where

 

manual shutoff valve was connected.

3.

Pressurize supply piping system by ei-

 

ther using compressed air or opening

 

propane/LP supply tank valve.

4.

Check all joints of gas supply piping

 

system. Apply mixture of liquid soap

 

and water to gas joints. Bubbles form-

 

ing show a leak.

5.

Correct all leaks at once.

Test Pressures Equal To or Less Than 1/2 PSIG

1.Close manual shutoff valve (see Fig- ure 14).

2.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

Shutoff

Valve

Closed

Figure 14 - Manual Shutoff Valve

Control

Valve Location

Propane/LP

Supply

Tank

the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or

turn the gas control knob. Never use

tools. If the knob will not push in or

turn by hand, don’t try to repair it,

call a qualified service technician or

gas supplier. Force or attempted re-

pair may result in a fire or explo-

sion.

D. Do not use this appliance if any part

has been under water. Immediately

call a qualified service technician to

inspect the appliance and to replace

any part of the control system and

any gas control which has been un-

der water.

Manual

Shutoff

Valve

Figure 15 - Checking Gas Joints

103112

9

Image 9
Contents What to do if YOU Smell GAS 6000 BTU/HR ModelsBlue Flame 6000 BTU/HR Vent Free PROPANE/LP GAS Heater Safety InformationProduct Identification Product FeaturesAIR for Combustion and Ventilation Local CodesUnusually Tight Construction Determining AIR Flow for Heater LocationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Wall Installing toInstalling Two Mounting Screws Installing to WallInstalling Bottom Mounting Screw Placing Heater On Mounting ScrewsMinimum Connecting to GAS SupplyPressure Testing Heater GAS Connections Pressure Testing GAS Supply Piping SystemFor Your Safety Read Before Lighting Checking GAS ConnectionsLighting Instructions Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at top Replacement Parts SpecificationsService Hints Service Publications TechnicalIllustrated Parts List Heater Exploded ViewODS/PILOT Model VP600B Parts ListBlue Flame 6000 BTU/HR Vent Free PROPANE/LP GAS Heater 103112 Keep this Warranty Warranty Information

6000 BTU/HR specifications

The Desa 6000 BTU/HR air conditioning unit is designed to provide efficient cooling solutions for small to medium-sized spaces. With its sleek design and powerful performance, this unit has become popular among homeowners and small businesses alike. One of the standout features of the Desa 6000 BTU/HR is its ability to cool spaces quickly and effectively, making it ideal for rooms up to 250 square feet.

The unit operates with a cooling capacity of 6000 BTUs per hour, which is sufficient to maintain comfortable temperatures even on the hottest summer days. This capacity ensures that the unit can handle varying humidity levels, making it versatile for different climates. The efficiency of the Desa air conditioner is reflected in its Energy Efficiency Ratio (EER), which often meets or exceeds industry standards, helping users save on energy bills.

Incorporating advanced technology, the Desa 6000 BTU/HR features a user-friendly digital thermostat that allows for precise temperature control. This ensures that users can set their desired comfort levels easily and monitor the current temperature through an intuitive display. Furthermore, the unit comes equipped with a remote control, providing added convenience for operating the air conditioner from a distance.

The Desa air conditioning unit also includes multiple fan speeds, allowing users to customize airflow according to their preferences. This feature is particularly useful for achieving the perfect balance between cooling efficiency and noise reduction. The integrated filter system ensures that the air circulated through the unit is clean, contributing to a healthier indoor environment. The washable filter is easy to maintain, promoting long-term performance.

Another notable characteristic of the Desa 6000 BTU/HR is its portability. The lightweight design and built-in caster wheels allow for easy movement from room to room, giving users flexibility to cool different areas as needed. This feature is especially beneficial for renters or those living in smaller homes where window installations may not be feasible.

With its combination of effective cooling power, advanced features, and user-friendly design, the Desa 6000 BTU/HR air conditioning unit stands out as a practical solution for achieving comfort during warmer months. Whether used in a bedroom, office, or small living space, this unit promises reliable performance and adaptability to meet the cooling needs of its users.