2.11 ELECTRICAL DIAGRAMShould the Economy 7 system not to be used, a separate 13 amp supply to each element will be required. Through a double pole fused isolating switch having a contact gap of at least 3mm on each pole.The immersion heater shall be installed with 85°C rubber insulated
Single Element
L1
N
THERMAL | THERMOSTAT |
| |
| ELEMENT |
| 3 kW |
| 240V~ |
FIG. 2.12
L1
N
L2
N
THERMAL | THERMOSTAT |
|
THERMAL | THERMOSTAT |
|
DAY ELEMENT
3 kW 240V~
NIGHT ELEMENT 3 kW 240V~
ECONOMY 7
FIG. 2.13
The thermostat(s) on the immersion heater(s) should be adjusted to trip at 60°C. This is the ideal temperature to prolong element life in hard water areas. Scale on the sheath builds up more rapidly at temperatures above this causing the element to overheat and premature failure can occur. Higher temperatures without additional controls would result in scalding.
In addition to the thermostat the thermal
has been corrected.