Ariston Unvented Hot Water Storage Cylinders manual Thermostat

Page 14

www.tradeplumbing.co.uk Call Sales On 08708034288

2.11 ELECTRICAL DIAGRAMShould the Economy 7 system not to be used, a separate 13 amp supply to each element will be required. Through a double pole fused isolating switch having a contact gap of at least 3mm on each pole.The immersion heater shall be installed with 85°C rubber insulated HOFR-sheathed flexible cable complying with Table 8 of BS 6141: 1991. Make the connection(s) to the immersion heater(s) as per FIG. 2.12 and FIG. 2.13. For High Capacity 500 litre models consult the wiring diagram on the reverse of the inspection panel.

Single Element

L1

N

THERMAL

THERMOSTAT

CUT-OUT

 

 

ELEMENT

 

3 kW

 

240V~

FIG. 2.12

L1

N

L2

N

THERMAL

THERMOSTAT

CUT-OUT

 

THERMAL

THERMOSTAT

CUT-OUT

 

DAY ELEMENT

3 kW 240V~

NIGHT ELEMENT 3 kW 240V~

ECONOMY 7

FIG. 2.13

The thermostat(s) on the immersion heater(s) should be adjusted to trip at 60°C. This is the ideal temperature to prolong element life in hard water areas. Scale on the sheath builds up more rapidly at temperatures above this causing the element to overheat and premature failure can occur. Higher temperatures without additional controls would result in scalding.

In addition to the thermostat the thermal cut-out will switch power off to the element should the thermostat malfunction, causing an excessive rise in water temperature. The thermal cut-out can be reset manually after the fault

has been corrected.

www.tradeplumbing.co.uk Call Sales On 08708034288

14

Image 14
Contents Unvented Hot Water Storage Cylinders Table of Contents Information personnel Ariston range is available in the following optionsInstallation Overall Dimensions ST Protech For floor standing modelsPlease check this before making any connection to the unit STD Protech STD/STD PROTECH/ITD 125-150-210-300 DirectSTD Protech STI/STI PROTECH/ITI 125-150-210-300 IndirectSTI Protech Expansion relief valve must be accounted for Call Sales On Secondary Return Discharge Pipework Worked Example MaximumProtech Electronic ANTI-CORROSION System 240V~Information for the END User Direct SystemsThermostat Wiring Scheme for 2 X 2 Port Motorised Valves Indirect SystemsKeston Potterton Caradon IdealGlowworm VaillantPage Maintenance Trouble-shootingImmersion Heaters Magneisum Anodes Classico model onlyThermal Cut-outs Unvented Controlss ThermostatsFault Finding Fault Possible Causes RemedyCall Technical InformationPage Technical Service Hot Line 0870 241 Manufacturer MTS Benelux sa/nv Belgium